8

BA-en-2075-1807_ES47

3. Installation and assembly

3.1 Assembling the power supply

The power supply is designed for wall mounting. Attach using the brackets 
provided (installation dimensions, see Fig. 2). The operating elements of 
the power supply and the terminals must be freely accessible at all times.

3.2 Ground connection

A permanent ground connection must be made via the ground connection 
(5, Fig. 1). The ground cable should have a minimum cross section of 
1.5 mm

2

3.3 Selecting the discharging bars

Eltex R47 discharging bars, R36 ion blower nozzles and R55 ion blower 
head for AC operation can be connected to the ES47 power supplies.

Fig. 2:

Installation dimen-
sions, ES47 
Power Supply

Z-

11

3409

by

!

[

Summary of Contents for BASIX ES47 Series

Page 1: ...Operating Instructions Discharging System BASIX Series ES47 Power Supplies for AC Operation BA en 2075 1807 F01033y ...

Page 2: ...2 BA en 2075 1807_ES47 ...

Page 3: ...8 3 1 Assembling the power supply 8 3 2 Ground connection 8 3 3 Selecting the discharging bars 8 3 4 Connecting the high voltage cable 9 3 5 Maximum active bar length and length of the high voltage cable 10 3 6 Connecting the supply voltage 10 4 Operation 11 4 1 Startup 11 5 Maintenance 12 6 Trouble shooting 13 7 Warranty 14 8 Technical specifications ES47 15 9 Dimensions 16 10 Spare parts and acc...

Page 4: ...impair production processes and need to be eliminated The ES47 power supply features the following characteristics 4 high voltage outputs stable 5 kV AC output voltage small dimensions easy installation stable design in IP54 Please read the operating instructions carefully before starting the instru ment This will help you prevent personal injuries and damage to property Please give us a call if y...

Page 5: ...igh voltage connections 4 pcs 3 1 Shown with high voltage plug connected 3 2 Shown as delivered 4 Supply voltage conductor 5 Ground connection 6 Mounting lug 7 Mounting bolts housing cover X1 Ground connection protective ground X2 High voltage base plate Fig 1 ES47 high voltage power supply for AC operation Z 113404by ...

Page 6: ...power supplies are not permitted Use only original Eltex spare parts and equipment 2 2 Identification of risks and hazards Possible risks and hazards resulting from the use of the power supplies are referred to in these operating instructions by the following symbols Warning This symbol appearing in the operating instructions refers to operations which if carried out improperly may result in serio...

Page 7: ...connected The operation of the bars can generate ozone The ozone concentra tion levels developing near the bars depend on many different factors such as site of installation bar current and voltage air circulation etc and can therefore not be specified in general terms If the maximum allowable concentration of ozone must be observed at the site of instal lation of the bar the concentration must be...

Page 8: ... the terminals must be freely accessible at all times 3 2 Ground connection A permanent ground connection must be made via the ground connection 5 Fig 1 The ground cable should have a minimum cross section of 1 5 mm2 3 3 Selecting the discharging bars Eltex R47 discharging bars R36 ion blower nozzles and R55 ion blower head for AC operation can be connected to the ES47 power supplies Fig 2 Install...

Page 9: ...of the power supply see Fig 1 Remove the nut from the connection at the high voltage cable Insert the connection into the provided opening of the housing Clamp the core of the high voltage cable to the high voltage socket X2 Fix the connection inside the unit with the locknut Plug the flat connector of the cable shielding onto ground connection X1 Warning Terminals at the housing that are not used...

Page 10: ...cting the supply voltage Connect the supply voltage via the power supply lead 4 Fig 1 using an earthing pin plug depending on country To ensure that no voltage is supplied to the bars when the material web is at rest enabling the supply voltage to the power supply via machine con tact is recommended If the material web is at rest or if the machine is not in operation no high voltage is supplied to...

Page 11: ...have been installed and assembled correctly The supply voltage can then be switched on Use the toggle switch 1 Fig 1 to switch on the power supply In the ON position the switch lights up green High voltage is now supplied to the dis charging bars The output voltage is now a constant 5 kV AC If the fuse is defective the switch will not light up ...

Page 12: ...for the check depend on the appli cation and must hence be defined by the user according to the operating conditions The power supply itself does not require any maintenance Check for correct ground connection Discharging bars To ensure the proper function of the discharging bars clean the bars at least once a week using compressed air and a brush with soft plastic bristles Refer to the operating ...

Page 13: ...rk Maintenance work must be car ried out by trained or qualified personnel Fault Cause Measure No high voltage Lamp in mains power switch lit transformer defective Lamp in mains power switch fails to light supply voltage not enabled or not con nected Defective fuse Inform Eltex Service Check supply voltage and connections Check connected cables cable connections and bars Replace fuse ...

Page 14: ... the operating and assembly instructions spe cified by Eltex have been observed The warranty period begins on the date of delivery In the event of defects occurring during the warranty period the units or defective components will be repaired at Eltex Defective components will be replaced and installed free of charge If repairs are required at the customer s premises the costs for sending a techni...

Page 15: ...Protection class Dimensions Weight UL Approval 230 V AC 50 60 Hz 115 V AC 60 Hz max 25 VA 5 kV AC depending on length of bar and length of high voltage cable see 3 5 max 2 4 mA at 5 kV 0 50 C 32 122 F 20 80 C 4 176 F max 80 r h non dewing approx 2 0 meters with earthing pin plug national version see name plate ground connecton on housing 4 pieces sheet metal steel with wall bracket IP 54 207 x 170...

Page 16: ...16 BA en 2075 1807_ES47 9 Dimensions Fig 5 Dimensions ES47 Power Supply Z 113409by ...

Page 17: ...5 specify cable length Plug X Kit for cutting high voltage cable to size without flexible tube for bar R47 Hexagonal crimper 5 41 mm Blanking plug M16 x 1 5 Nut M16 x 1 5 Mains cable gland Fuse F1 115 V 0 315 A T IEC 60127 2 3 Fuse F1 230 V 0 63 A T IEC 60127 2 3 Accessory Kit of fixing screws and cover Operating instructions specify language KE Xy 113259 102952 113399 104974 MCH02176 ELM00722 105...

Page 18: ...18 BA en 2075 1807_ES47 ...

Page 19: ......

Page 20: ... 67 69 D 79576 Weil am Rhein Phone 49 0 76 21 79 05 230 Fax 49 0 76 21 79 05 330 eMail static control eltex com Internet www eltex com Eltex offices and agencies The addresses of all Eltex agencies can be found on our website at www eltex com Z01007y ...

Reviews: