background image

g

g

Teach-in controller:

Press the left button LRN/CLR about 
0.5 seconds and then release, the LED 
lights up. Send a teach-in telegram from 
the controller, the LED goes out.
At teaching in, the confi rmation telegrams 
are automatically switched on and sent 
with their own ID.
Exit the learn and clear mode immediately 
by briefl y pressing the LRN/CLR button. 
The routine exits the learn and clear mode 
automatically after 60 seconds.

To prevent unintentional teach-in, teach 
in pushbuttons by 'double-clicking' 
(pressing rapidly twice in succession).

1.  Briefl y press the left button LRN/CLR 

button 2 times, the LED blinks 2 times 
for confi rmation.

2.  Select the desired teaching-in function 

with the right button.

3.  Press the taught-in button with 'double 

click'. The LED goes out.

Unencrypted and encrypted sensors can 
be taught-in.

Teach in encrypted sensors:

1.   Press the left button LRN/CLR for 

 approximately 0.5 seconds and then 
 release, the LED lights up.

2.  Briefl y press the right button ON/OFF 

5 times, the LED fl ashes very excitedly.

3.  Enable encryption of the sensor within 

120 seconds. The LED goes out.

   Attention! The power supply should not 

be turned off.

4.  Now teach-in the encrypted sensor as 

described among teaching-in sensors.

If further encrypted sensors should be 
taught-in, go back to point 1.
With encrypted sensors, use the 'rolling 
code', i.e. the code changes in each 
 telegram, both in the transmitter and in 
the receiver.
If a sensor sends more than 50 telegrams 
when the actuator is not enabled, the 
 sensor is no longer recognised by the 
 enabled actuator and you must repeat 
teach-in as 'encrypted sensor'. It is not 
necessary to repeat the function teach-
in.

Switch on/off repeater:

Press and hold the right button ON/OFF and 
plug the FSSA-230V into the socket. Switch 
repeater on or off. The LED lights up for 
2 seconds to indicate the status = repeater 
off (as-delivered state) or for 5 seconds = 
 repeater  on.

Switch on/off confi rmation telegrams:

Press and hold down the left button LRN/CLR 
and the right button ON/OFF  together and 
plug the FSSA-230V in the socket. Confi rma-
tion telegrams are  switched on and off. The 
LED lights up for 0.5 seconds = confi rmation 
telegrams OFF (as-delivered state) or for 
2 seconds = confi rmation telegrams ON to 
 indicate the status.

Confi rmation telegrams:

The FSSA-230V sends a feedback  message 
containing its own ID to the Eltako wireless 
network. The digits 0x70 are sent when the 
relay is switched on. The digits 0x50 are sent 
when the relay is switched off. 

Teach in confi rmation telegrams in other 
actuators or in a controller:

Press the right button ON/OFF to change the 
switch position and send the con fi rmation 
telegram at the same time.

 

 May only be used in closed 
dry rooms. 
The socket must be easily 
 accessible.
Don’t insert in a row.

!

Frequency 868.3 

MHz 

Transmit power 

max. 10 mW

Hereby, Eltako GmbH declares that the radio 
equipment type FSSA-230V is in 
 com pliance with Directive 2014/53/EU. 
The full text of the EU declaration of 
 conformity is available at the following 
 internet address: eltako.com

WEEE-Reg.-Nr. DE 30298319

Must be kept for later use!

Eltako GmbH

D-70736 Fellbach

Technical Support English:

   +49 711 94350025
 [email protected]

eltako.com

42/2022 Subject to change without notice.