background image

!

  Parameters for operating with FAH60

  Parameters for operation of FWS61

  Add or change sensors

When an actuator is ready for 
teach-in (the LED fl ashes at a 
low rate), the very next incoming 
signal is taught-in. Therefore, 
make absolutely sure that you 
do not activate any other sensors 
during the teach-in phase.

Cable fi xation

The cable must be fastened with standard 
cable ties (width < 3,6 mm).

ELTAKO GmbH hereby declares that the 
products that relates to this operating 
manual, are in compliance with the 
 essential requirements and other rele-
vant provisions of directive 1999/5/EC. 

A copy of the EU declaration of confor-
mity can be requested at the address 
below.

Must be kept for later use!

Eltako GmbH

D-70736 Fellbach

Technical Support English:

  Michael Thünte +49 176 13582514
 [email protected]

  Marc Peter +49 173 3180368
 [email protected]

eltako.com

36/2016 Subject to change without notice.

Reviews: