When an alarm occurs,
a beep sounds
every 1-second. The beep stops auto-
matically after 3 minutes (the time starts
from zero at each incoming alarm tele-
gram) but an alarm confirmation telegram
(if activated) is still sent every 1 second
for ON and every 9 seconds for OFF.
Switch alarm off:
Press
bottom direction pushbutton
or
press the pushbutton under the front
panel for 10 seconds and then release.
The alarm stops immediately.
When teaching in
wireless window
contacts
or
window handles,
the alarm
switches on after a response lag time of
10 seconds when a window is opened.
If you close the window, the alarm does
not stop automatically. Switch it off
using 'Press bottom direction push button'.
After
wireless window/door contacts
FTKB-hg
are taught in, the intelligent
intrusion detector is active even if the
alarm system is disabled. An alarm
sounds when the window is opened in
locked and tilt position.
When teaching in
FB65B or FBH65SB
motion sensors,
the alarm switches on
after a response lag time of 10 seconds
when motion is detected.
Switch off the alarm using 'Press bottom
direction pushbutton'.
If a
smoke detector FRWB or water
sensor
is taught-in, the contact closes
immediately after receiving the alarm
telegram. In the event of an alarm end
telegram, the alarm does not stop auto-
matically. Switch it off using 'Press bot-
tom direction pushbutton'.
If a
doorbell pushbutton
is pressed, an
acoustic signal is generated in an 2 se-
conds interval until the pushbutton is
released. (min. 3 times) If the doorbell
pushbutton stays pressed, the acoustic
signal stops after 1 minute. Alarm has
always priority over the doorbell.
When an
universal pushbutton
is
pressed, the alarm switches on after a
response lag time of 10 seconds. Switch
off the alarm using 'Press bottom direction
pushbutton'.
Teach in signal generator in actuators:
Press the pushbutton under the front
panel for 5 seconds and then release.
Send is signalled by two beeps.
Teach-in telegram: 0xE0400D80
Data telegram according to EEP:
A5-38-08
(ORG7) 0x01000008 = Alarm on
0x01000009 = Alarm off
Unblock teach-in mode for a wireless
actuator with FIUS55E:
Press the pushbutton under the front
panel for 20 seconds and then release.
(ORG7) 0x01000028 = unblock
EnOcean wireless
Frequency
868.3 MHz
Transmit power
max. 10 mW
Hereby, Eltako GmbH declares that the
radio equipment type FIUS55E is in
compliance with Directive 2014/53/EU.
The full text of the EU declaration of
conformity is available at the following
internet address: eltako.com
Must be kept for later use!
Eltako GmbH
D-70736 Fellbach
Technical Support English:
Michael Thünte +49 176 13582514
[email protected]
Marc Peter +49 173 3180368
[email protected]
eltako.com
40/2019 Subject to change without notice.