When an alarm occurs, 

a beep sounds 

every 1-second. The beep stops auto-
matically after 3 minutes (the time starts 
from zero at each incoming alarm tele-
gram) but an alarm confirmation telegram 
(if activated) is still sent every 1 second 
for ON and every 9 seconds for OFF.

Switch alarm off: 

Press 

bottom direction pushbutton

 or 

press the pushbutton under the front 
 panel for 10 seconds and then release. 
The alarm stops immediately.

When teaching in 

wireless window 

 contacts 

or

 window handles, 

the alarm 

switches on after a response lag time of 
10 seconds when a window is opened.
If you close the window, the alarm does 
not stop automatically. Switch it off 
using 'Press bottom direction push button'. 
After 

wireless window/door contacts 

FTKB-hg

 are taught in, the intelligent 

 intrusion detector is active even if the 
alarm system is disabled. An alarm 
sounds when the window is opened in 
locked and tilt position.
When teaching in 

FB65B or FBH65SB 

motion sensors, 

the alarm switches on 

after a response lag time of 10 seconds 
when motion is detected.
Switch off the alarm using 'Press bottom 
direction pushbutton'.
If a 

smoke detector FRWB or water 

sensor

 is taught-in, the contact closes 

immediately after receiving the alarm 
 telegram. In the event of an alarm end 
telegram, the alarm does not stop auto-
matically. Switch it off using 'Press bot-
tom direction pushbutton'.
If a 

doorbell pushbutton

 is pressed, an 

acoustic signal is generated in an 2 se-
conds interval until the pushbutton is  
released. (min. 3 times) If the doorbell 
pushbutton stays pressed, the acoustic 
signal stops after 1 minute. Alarm has 
always priority over the doorbell.
When an 

universal pushbutton

 is 

pressed, the alarm switches on after a 
response lag time of 10 seconds. Switch 
off the alarm using 'Press bottom direction 
pushbutton'.

Teach in signal generator in actuators: 

Press the pushbutton under the front 
panel for 5 seconds and then release. 

Send is signalled by two beeps.
Teach-in telegram: 0xE0400D80
Data telegram according to EEP:  
A5-38-08
(ORG7)  0x01000008 = Alarm on 

0x01000009 = Alarm off

Unblock teach-in mode for a wireless 
actuator with FIUS55E: 
Press the pushbutton under the front 
panel for 20 seconds and then release.
(ORG7) 0x01000028 = unblock

EnOcean wireless

Frequency  

868.3 MHz 

Transmit power 

max. 10 mW

Hereby, Eltako GmbH declares that the 
radio equipment type FIUS55E is in 
compliance with Directive 2014/53/EU. 

The full text of the EU declaration of 
conformity is available at the following 
internet address: eltako.com

Must be kept for later use!

Eltako GmbH

D-70736 Fellbach

Technical Support English: 

  Michael Thünte +49 176 13582514 
 [email protected]

  Marc Peter +49 173 3180368
 [email protected]

eltako.com

40/2019 Subject to change without notice.