background image

1

Installation manual

Mori HR

PRECAUTIONS FOR INSTALLATION, USE AND MAINTENANCE

G

G

Read this manual carefully before using the product and keep it 

in a safe place for reference.  

This product was constructed up to standard and in compliance 

with regulations relating to electrical equipment and must be 

installed by technically qualified personnel. 

The manufacturer assumes no responsibility for damage to 

persons or property resulting from failure to observe the 

regulations contained in this booklet.

• The device should not be used for applications other than those specified in this manual.

• After removing the product from its packaging, verify its condition. In case of doubt, 

contact a qualified technician. Do not leave packaging within the reach of small children 

or people with disabilities.

• Do not touch the appliance with wet or damp hands/feet.

• This appliance can be used by children aged from 8 years and above and persons with 

reduced physical, sensory or mental capabilities or lack of experience and knowledge 

if they have been given supervision or instruction concerning use of the appliance 

in a safe way and understand the hazards involved. Children shall not play with the 

appliance. Cleaning and user maintenance shall not be made by children without 

supervision.

• Do  not  use  the  product  in  the  presence  of  inflammable  vapours,  such  as  alcohol, 

insecticides, gasoline, etc...

• If any abnormalities in operation are detected, disconnect the device from the mains 

supply and contact a qualified technician immediately. Use original spare parts only for 

repairs.

• The electrical system to which the device is connected must comply with regulations.

• Before connecting the product to the power supply or the power outlet, ensure that:

  - the data plate (voltage and frequency) correspond to those of the electrical mains

  - the electrical power supply/socket is adequate for maximum device power. If not, 

contact a qualified technician.

• The  device  should  not  be  used  as  an  activator  for  water  heaters,  stoves,  etc.,  nor 

should it discharge into hot air/fume vent ducts deriving from any type of combustion 

unit. It must expel air outside via its own special duct.

• Operating temperature: -20°C up to +50°C.

• The device is designed to extract clean air only, i.e. without grease, soot, chemical or 

corrosive agents, or flammable or explosive mixtures. 

• Do not leave the device exposed to atmospheric agents (rain, sun, snow, etc.).

• Do not immerse the device or its parts in water or other liquids. 

• Turn off the main switch whenever a malfunction is detected or when cleaning.

• For  installation  an  omnipolar  switch  should  be  incorporated  in  the  fixed  wiring,  in 

accordance with the wiring regulations, to provide a full disconnection under overvoltage 

Summary of Contents for Mori HR 100

Page 1: ...en without supervision Do not use the product in the presence of inflammable vapours such as alcohol insecticides gasoline etc If any abnormalities in operation are detected disconnect the device from...

Page 2: ...om or in different rooms i e living room and bedroom The unit is suitable for installation on an outside wall To achieve the best possible ventilation the unit should operate continuously and only sto...

Page 3: ...if required Fig 18D 5 Constant run with alternate flow and heat retention on Speed 2 with boost to Speed 3 triggered by external switching device ordered separately if required Fig 18E 6 Operation usi...

Page 4: ...nised way Wiring diagram as per Fig 18 SYNCHRONISATION IN CASE OF INSTALLATION WITH CONTROLLER DIMENSIONS 164 q A 270 510 164 q 108 O mm 164 q C D E External grille 270 510 164 q 164 q 108 O mm B Mori...

Page 5: ...5 INSTALLATION 1 CONTENUTO IMBALLO MODELLO MORI HR Mori HR 100 Mori HR 150 4 3 5 min 108mm HR100 min 158mm HR150 INDOOR OUTDOOR 1 2 2 insulation foam 6 7 5x40mm 8x10mm...

Page 6: ...6 8 9 10 11 100mm HR100 115mm HR150 12 13 14 15...

Page 7: ...S 2 S 1 G N D N L S 3 S 2 S 1 G N D N L SPEED 1 FIXED SPEED 2 FIXED SPEED 3 FIXED S 3 S 2 S 1 G N D N L CTRL S S1 S2 S3 II I N L OK 1 1 1 S3 S2 S1 18F 18A 18B S 3 S 2 S 1 G N D N L S 3 S 2 S 1 G N D...

Page 8: ...OK S 3 S 2 S 1 G N D N L CTRL S 1 1 1 S3 S2 S1 18G UNIT 1 UNIT 2 S 3 S 2 S 1 G N D N L CTRL S S1 S2 S3 II I N L OK 1 1 1 S3 S2 S1 18F FOGLIO ISTRUZIONI JUMPER POSITION A 20A EXTRACT 21 AGGIUNTA FOGLI...

Page 9: ...9 23 CLICK 24 25 27 26...

Page 10: ...10 5x40mm 3 5mm EXTERNAL GRILLE 29 28 30 31 32 TO RESET OF THE SYNCHRONIZATION OF THE UNITS OPTION 2 33 TO RESET OF THE SYNCHRONIZATION OF THE UNITS OPTION 1...

Page 11: ...11 34 35 36 37 38 I 39 40 41 I FILTER CLEANING MAINTENANCE Can be carried out by the user...

Page 12: ...12 71 48 49 44 45 46 42 43 47 HEAT EXCHANGER CLEANING SERVICE Must be carried out only by technically qualified personnel...

Page 13: ...13 71 52 56 50 53 51 100mm HR100 115mm HR150 54 55 Fig 57 149 SEN CTRLS I II REMOTE CONTROLLER on request HIGHLY RECOMMENDED...

Page 14: ...or 1 n2 Control typology Manual control no DCV o1 Maximum internal leakage rate N A o2 Maximum external leakage rate 1 p1 Internal mixing rate N A p2 External mixing rate N A q Visual filter warning N...

Page 15: ...ing of the materials that make up the equipment Improper disposal of the product by the user may result in administrative sanctions as provided by law DISPOSAL AND RECYCLING GUARANTEE The product is o...

Page 16: ...Elta Fans Limited Building Services 46 Third Avenue Pensnett Trading Estate Kingswinford West Midlands DY6 7US United Kingdom T 44 0 1384 275800 F 44 0 1384 275810 E bs eltafans co uk 000830 07 0718...

Reviews: