Door activity sensor
Make sure that the magnet part is mounted on the
“
door
”
(the part that is going to
open) and the sensor part is mounted on the frame. For double doors, put one part on
each door.
The distance between magnet and sensor should, if possible, not exceed 10mm. Make
sure that the magnet and reed switch are mounted next to each other. Detection range
will be affected by the materials of the door and frame, different materials result in
different ranges.
The reed switch is on the end of the sensor
without
the stripe. The
magnet needs to face this side of the sensor (see image).
Water leak sensor
Make sure that the back panel is mounted on the surface where the water may leak. The
sensor element that detects the leak is placed on the back panel. For example, if EMS is
going to monitor water leak from a dishwasher, place the back panel onto the floor
under the machine.
Temperature/humidity sensor
Place the device in an open space on a wall, under a desk or on any other flat surface.
Make sure that the sensor is not faced by direct sunlight or placed near air vents or
other places where it may measure values that is not representative for the rest of the
room.