ELSYS.se ERS Eye Operating Manual Download Page 3

 

Elektroniksystem i Umeå AB Industrivägen 12, 90130 Umeå, Sweden 
E-mail

[email protected]

 

ǀ

 Web

www.elsys.se

 

Contents

 

 

Important safety information ...........................................................................................2 

Description .........................................................................................................................4 

Main features of ERS Eye .......................................................................................................... 5

 

Installation ..........................................................................................................................6 

Service and maintenance .................................................................................................7 

Sensor configuration .........................................................................................................8 

NFC Configuration ....................................................................................................................... 8

 

Over the air configuration .......................................................................................................... 9

 

Application parameters............................................................................................................... 9

 

Sensor behavior .................................................................................................................9 

NFC Read / Write ........................................................................................................................ 9

 

Sensor startup ........................................................................................................................... 10

 

Sampling mode / Periodic measurement ............................................................................. 11

 

Schedule Transmission............................................................................................................. 11

 

Motion detection range ............................................................................................................ 12

 

PIR Lens detection pattern ...................................................................................................... 12

 

Grid-Eye....................................................................................................................................... 13

 

Specifications .................................................................................................................. 15 

Sensor payload format ............................................................................................................. 15

 

Regulations ...................................................................................................................... 16 

Legal Notices ............................................................................................................................. 16

 

Declaration of conformity ........................................................................................................ 16

 

 

Summary of Contents for ERS Eye

Page 1: ...ektroniksystem i Umeå AB Industrivägen 12 90130 Umeå Sweden E mail support elsys se ǀ Web www elsys se Specifications in this document are subject to change without notice Elektroniksystem i Umeå AB 2020 ...

Page 2: ...attery should be removed from the device if it is not to be used for an extended period Otherwise the battery might leak and damage the equipment Never leave a discharged battery in the battery compartment The device must never be subjected to shocks or impacts To clean the device wipe with a soft moistened cloth Use another soft dry cloth to wipe dry Do not use any detergent or alcohol to clean t...

Page 3: ...vice and maintenance 7 Sensor configuration 8 NFC Configuration 8 Over the air configuration 9 Application parameters 9 Sensor behavior 9 NFC Read Write 9 Sensor startup 10 Sampling mode Periodic measurement 11 Schedule Transmission 11 Motion detection range 12 PIR Lens detection pattern 12 Grid Eye 13 Specifications 15 Sensor payload format 15 Regulations 16 Legal Notices 16 Declaration of confor...

Page 4: ... The sensor measures temperature humidity light intensity and detects occupancy It can detect occupancy based on body heat not only by movement ERS Eye is a battery powered device and is designed to be mounted on the ceiling It is equipped with NFC Near Field Communication and can easily be configured from a smartphone The barcode contains DevEUI and sensor type This label is located at the back o...

Page 5: ...IR sensor Detects occupancy using a Grid Eye infra red sensor Can detect occupancy even if people are sitting standing still Easy installation Easy configuration May be installed on a ceiling or any surface Battery powered Long range communication Configurable over NFC Configurable over the air Five years of battery life Supported channel plans US902 928 EU863 870 AS923 AU915 928 KR920 923 RU864 I...

Page 6: ...ler area for possible detection 1 Remove the back panel of the sensor with a small screwdriver 2 Mount the back panel securely to the wall with at least 2 appropriate screws using some of the six mounting holes Note ERS Eye will calculate its first background picture 15s after inserting the batteries It is preferable if the room is unoccupied at this time Otherwise it will take maximum 24h to reca...

Page 7: ...at you use two for best performance and battery life Use battery slot A if only one battery is used Caution Using batteries other than the ones provided may result in loss of performance and battery life and also damage to the device Dispose of properly observing environmental protection rules 4 Attach the sensor part to the back panel Service and maintenance No serviceable parts inside If service...

Page 8: ...r NFC Configuration 1 Download ELSYS Sensor Settings application from Google Play and install it on a smartphone or tablet The device must support NFC 2 Enable NFC on the device and start the application 3 Place your device on top of the NFC antenna on the sensor 4 Remove the device Current settings will be displayed in the application 5 Use the application to change any settings if needed 6 Quick...

Page 9: ...riting NFC configuration data to the sensor it starts a timer and delays its action 5 seconds 2 After the delay the sensor determines if the NFC data has changed or not If it has changed the sensor reboots and starts from power up 3 Write your settings in the application and then locate the NFC antenna of the phone and sensor Keep the two devices close and don t move them to get the best connectiv...

Page 10: ... NFC chip when something changes in the sensor or if NFC data is corrupted by an NFC writer or phone The sensor always writes the new configuration to NFC chip at startup 3 When the configuration is done the sensor tries to join the network if OTAA Over the Air Activation is enabled 4 The sensor LED flashes orange when it tries to join a network It will try to join every 10 seconds initially This ...

Page 11: ...sensor makes periodic measurements according to the user configurations Schedule Transmission The sensor transmits the data according to the user configurations Note The configured sending interval can be overridden by network limitations Due to this the spreading factor and sending interval settings might result in longer intervals than intended ...

Page 12: ...re it will face direct or reflected sunlight Avoid installing near windows air conditioning or heating vents Such placements will give false values The PIR can cause self trigger if sensors are placed too close to each other Keep this in mind when you mount or test the sensors Note The PIR Lens has a blanking time of 20 seconds right after motion event and transmission Any movements during this ti...

Page 13: ...d image is calibrated The Grid Eye heat map image will be postponed 5 minutes after every PIR motion detection Room occupancy is set to 1 as long as motion is detected Whenever occupancy value is changed the ERS Eye will schedule transmission and go into sleep mode No triggered transmission will be done as long as occupancy value remains unchanged Periodic transmission will send all values includi...

Page 14: ...14 Elektroniksystem i Umeå AB Industrivägen 12 90130 Umeå Sweden E mail support elsys se ǀ Web www elsys se ...

Page 15: ...IN865 HK923 Range 8 km Recommended installation height Ceiling 5m above detection area Operating conditions 0 to 40 C 0 to 85 RH non condensing Detection range 5 m Infrared accuracy 2 5 C Detection field of view 60 Temperature range 0 40 C Temperature resolution 0 1 C Temperature accuracy 0 2 C Humidity range 0 100 Humidity resolution 0 1 RH Humidity accuracy 2 RH Light range 4 2000 Lux Light reso...

Page 16: ...ce ELSYS reserves all rights to revise or update its products software or documentation without any obligation to notify any individual or entity ELSYS and ELSYS logo are trademarks of Elektroniksystem i Umeå AB All other brands and product names referred to herein are trademarks of their respective holders Declaration of conformity Hereby Elektroniksystem i Umeå AB declares that ERS Eye complies ...

Reviews: