User keys, selection key and symbols

 

You can navigate through the menu using the 

user keys 

 and the selection key  .

Symbol

Meaning

Navigate to the left or the right on each 
level using the user keys.

Briefly pressing the selection key selects 
a sub-menu.
Holding the selection key pressed down 
switches the display back to the previous 
menu.

Briefly pressing the selection key selects 
a sub-menu.

Holding the selection key pressed down 
switches the display back to the previous 
menu.

,  , 

Keys inactive

=

RF module/communication is active

=

RF module/communication is inactive

=

RF  communication – pairing  successful
Invalid data

Alarm

Low index battery. This symbol is only 
displayed when battery power is low.

T

 Temperature out of operational range

p

Pressure out of operational range

*

Multiple sensor data out of operational 
range

 

In each menu, the meaning of the symbols for 
the keys is described in the information area.

 

In the main screen under “General instructions”, 
all the symbols are explained.

Navigating within the menu

 

The menu is constructed hierarchically.

 

The “Current meter reading” main screen appears 

when switching on the index.

 

If you are in a different menu, the display will 
automatically change back to the main screen 
when no user key has been pressed for 30 s, 
and switches off after a further 30 s.

 

You can navigate from the main screen to the 

various menus, such as “Date and time (UTC)” 

using the user keys 

.

Menu overview



Current meter reading

 

General instructions

Date and time (UTC)

Past meter readings

Monthly

Tariff information
Billing information
Metering point identification

Daily

Hourly

Main menu

Current meter reading

 

UTC = coordinated universal time + X = offset 
for conversion to local time.

 

The absolute meter reading and optionally the 

current tariff are indicated in the main screen.

 

This appears when switching on the index.

 

You can receive information about the symbols by 

pressing the selection key   and the user keys 

, or see page 3 (User keys, selection 

key and symbols).

Date and time (UTC + X)

 

Information on the date and time display.

 

The current date and time appears when the 

selection key   is pressed. 

 

Local time is supported.

 

Daylight saving time can be supported.

 

For further information, contact the meter op-
erator.

*Date and time: (UTC + X)

20–04–2013

07:15:30

 

The date is given in the format DD-MM-YYYY.

Summary of Contents for themis plus

Page 1: ...ns may only be carried out by qualified gas technicians Electrical interventions may only be carried out by qualified electricians Conversion spare parts All technical changes are prohibited Only use OEM spare parts Transport On receipt of the product check that the delivery is complete see page 2 Part designations Report any transport damage immediately Storage Store the product in a dry place Am...

Page 2: ...for use in po tentially explosive atmospheres For the exact use zone see ATEX sticker on the diaphragm gas meter or see Operating instructions for diaphragm gas meters BK G1 6 to BK G25 http docuthek kromschroeder com doclib main php language 1 folderid 400041 by_ class 2 by_lang 1 Instruction Manual Industrial Diaphragm Gas Meters Type BK G40 BK G65 BK G100 and Type BK G40T BK G65T BK G100T http ...

Page 3: ...ally The Current meter reading main screen appears when switching on the index If you are in a different menu the display will automatically change back to the main screen when no user key has been pressed for 30 s and switches off after a further 30 s You can navigate from the main screen to the various menus such as Date and time UTC using the user keys Menu overview Current meter reading Genera...

Page 4: ...ss further information Here the active tariff program is displayed as are the date and time of activation Tariff information ID Green Spring Demo From 01 01 2000 06 00 By briefly pressing the selection key you can visualize the consumption data Consumption results F01 0 00m3 F02 0 00m3 F03 0 00m3 UES 0x0240000000000000 In lines F01 to F03 the current absolute gas consumption values of the relevant...

Page 5: ...it its pulses the pulses are buffered and will be transmitted afterwards when con sumption is low Pin assignment Pin 1 2 4 6 not connected Pin 3 output Pin 5 output 3 6 4 5 2 1 To connect the pulse output use a socket type IEC 60130 9 Assistance in the event of malfunction Fault Cause Remedy Possible faults and suggested solutions The symbol is displayed If the symbol appears next to a measured va...

Page 6: ...id 400041 by_class 2 by_ lang 1 Instruction Manual Industrial Diaphragm Gas Meters Type BK G40 BK G65 BK G100 and Type BK G40T BK G65T BK G100T http docuthek kromschroeder com doclib main ph p language 1 folderid 400045 by_class 2 by_ lang 1 ATEX explosion protection The index EI3 is certified as an ATEX subassembly and is marked as follows II 2 G Ex ib IIA T4 Gb Specific explosion protection mark...

Page 7: ...GB 7 D GB ...

Page 8: ...ng Limited Paton Drive Tollgate Business Park Beaconside Stafford ST16 3EF T 44 1785 275200 F 44 1785 275305 jeavons info gb elster com www elstermetering co uk Ireland Active Energy Control Ltd Unit 4 Clare Marts Quin Road Ennis Co Clare T 353 65 6840600 F 353 65 6840610 info aec ie www aec ie We reserve the right to make technical modifications in the interests of progress Contact ...

Reviews: