10 Jumper 

 

 J1 

 J2 

 J3 

   J1  J2  J3   

 

                      

up 

up 

up 

 Analogue Modem / ISDN / Ethernet / CL 

up 

                    

up 

down  up 

 GSM Modem 

 

                    

down  up 

up 

 Setting parameters for analogue modem / ISDN / Ethernet 

down                      

down  down  up 

 Setting parameters for GSM Modem 

 

                      

any 

down  Reserved 

11 Modem Reset 

11.1 Modem-Watchdog 

 
In EM260/GSM with 

Wavecom-Adapterboard

 

starting from

 V1.2,

 a 

Watchdog function 

is 

implemented ex-works. The watchdog controls 
the modem function and resets the modem in the 
case of a failure. 
The watchdog is active if the jumper 

”JP7“

 

(“

Watchdog

“) is in the position “

enabled

“. 

 
 
 

11.2  Cyclical modem reset via output 4 of the EK260 

 
After activating the modem reset function the modem is restarted once a day via output 4 of the 
volume corrector. Time and duration of the modem reset are defined by the time window 2 of the 
EK260. If time window 2 is used to control the modem reset, it can no longer be used as a call 
acceptance window. In this case, call acceptance is exclusively defined by time window 1. 
 

)

 

In EM260 with 

Wavecom adapter board 

starting from 

V1.2,

 a 

watchdog function 

(refer 

to chapter 11.1) is implemented ex-works. The watchdog controls the modem function 
and resets it in the case of a failure. 
The presence of the watchdog makes the cyclical modem reset via output 4 of the EK260 
unnecessary. Output 4 of the EK260 can still be used for call acceptance. 

)

 

The modem reset function should be activated only if necessary (if manually operated 
modem resets have repeatedly been necessary to ensure the accessibility of the 
modem)! 
Ex-works the modem reset function is not activated! 

 
To activate the modem reset function, it is necessary to send a special parameter file to the 
EK260 and to modify the wiring between the EM260 and the EK260 (see below). 
 
Before activating the modem reset function, the following conditions must be fulfilled: 

ƒ

  The version number of the Wavecom-Integra-Adapter board (ID no. 73018344) inside the 

EM260 must be 1.1 or higher. 

ƒ

  On a Wavecom-Integra-Adapterboard V1.1 the soldering pad LF7 must be short-circuited, 

e.g. by a 0 Ohm resistor. 

ƒ

  In the case of an EK260 V2.2x, the modem reset function cannot be activated when a SIM 

card with an active PIN is in use. 

Jumper „JP7“ (Watchdog) 

Summary of Contents for EM260

Page 1: ...ÅÆ EK260 3 4 WIRING OF EM260 S COMMUNICATION INTERFACE 3 5 SETTINGS OF THE INTERNAL SERIAL INTERFACE IN THE EK260 3 6 SETTING THE PARAMETERS FOR THE COMMUNICATION MODULE 4 7 REPLACEMENT OF COMMUNICATION MODULES 5 8 POWER SUPPLY 5 9 OPERATING STATUS DISPLAY 5 10 JUMPER 6 11 MODEM RESET 6 11 1 Modem Watchdog 6 11 2 Cyclical modem reset via output 4 of the EK260 6 12 OPERATING AN EM260 WITH INTEGRATE...

Page 2: ...ble When assembling the front cover ensure that the flat strip cable for connecting the LEDs integrated into the front transparent film is plugged into the 4x1 pin strip ST8 In the GSM modem the SIM eject button is next to the SIM insert carriage on the right 2 Features Modem for use with ELSTER LIS 100 and LIS 200 end devices Internal TTL interface for one of the following communication modules S...

Page 3: ...is delivered separately for additional installation beside an EK260 the internal serial interface of the EK260 must be set in accordance with the software version of the EK260 and with the type of communication module integrated in the EM260 The serial interface of the EK260 must be parameterised before the EM260 is connected to the EK260 and switched on For this purpose the parameter software Win...

Page 4: ...le Then you can select the parameter file WPP which fits to your application communication module version of EK260 Example EM260 Analogue modem with EK260 V2 51 Æ EK260_2v5 EM260 int Analog Modem Insys _a WPP Before disconnecting the button Init modem should be pressed Interface Modem initialisation Æ after it is disconnected the EK260 sends the parameters to the communication module The parameter...

Page 5: ... 90 260 VAC version 18 30 VDC version PE PE 9 Operating status display Green LED Power on Yellow LED Ring Online GSM status depending on which communication module Modem is integrated yellow Online LED has the following meanings Analogue Modem ISDN Ethernet LED status Meaning off no connection flashing briefly ringing signal on online data transfer NB when a CL interface is in use the Online LED i...

Page 6: ...ined by time window 1 In EM260 with Wavecom adapter board starting from V1 2 a watchdog function refer to chapter 11 1 is implemented ex works The watchdog controls the modem function and resets it in the case of a failure The presence of the watchdog makes the cyclical modem reset via output 4 of the EK260 unnecessary Output 4 of the EK260 can still be used for call acceptance The modem reset fun...

Page 7: ...ameter file to be used depends on the software version of the EK260 EK260_yvy Funktion Modem Reset täglich EM260_x WPP where yvy software version of the EK260 e g 2v5 and x latest file index For a cyclical modem reset output 4 of the EK260 must be connected to the modem reset input Æ Wiring instructions see below Wiring instructions for cyclical modem reset If a cyclical modem reset is to be carri...

Page 8: ...l for lead with cross section 0 5 1 5 mm2 Power supply 90 260 VAC L N PE 18 30 VDC PE screw terminal for lead with cross section 0 5 1 5 mm2 Synthetic housing standard ABS with metallised surface inside IP65 in accordance with EN60529 EMV cable fitting for shielded cable otherwise synthetic cable fittings Ambient temperature with analogue modem INSYS i module Modem 0 50 C with ISDN adapter TA HUX ...

Reviews: