EK280
Application Manual
39
6.4
Time-synchronous output
Each of the outputs 1 to 4 (terminals DA1 to DA4) can be programmed as a time-synchronized output.
6.4.1
Parameterization
Parameterization is carried out via the keyboard on the EK280.
Alternatively, parametrization can be carried out using the
enSuite
program. The paths which are subsequently
described can be found in
enSuite
under "
Parameterize online
" > "
Parameters
".
a)
Setting up the output mode:
Move the cursor to the tab "
Serv.
" and subsequently via the following path to the mode for the
corresponding output
"
Md.O1
"
to
"
Md.O4
"
:
Serv.
Outputs
Output 1
Md.O1
Serv.
Outputs
Output 2
Md.O2
Serv.
Outputs
Output 3
Md.O3
Serv.
Outputs
Output 4
Md.O4
i
The time-synchronized outputs of the EK280 can be operated with active or inactive logic. The
output mode must be programmed accordingly for this purpose (see below).
Press the ENTER
button. The actual parameterized value flashes.
Press one of the arrow buttons
or
until the text
"time sync+"
(Logic active) or
"time sync-"
(Logic inactive) flashes.
Press the ENTER button to confirm the set value. It is possible to abort the entry by pressing the
ESC button.
d)
Setting up the source for the output:
i
Parametrization of the source for the output via the EK280 keyboard is only possible with
software version 2.20 or later.
Older software versions may be programmed using enSuite via
"
Parameterize online
" >
"
Parameters
"
and the paths described (see Chapter 6.4.1, 0)
When in the corresponding menu press the
button until
"Sc.O1
",
"Sc.O2
",
"Sc.O3
", or
"Sc.O4
" is
displayed.
Press the ENTER
button. The actual parameterized value flashes.
Move the cursor to the digits using the
or
arrow keys and update them using the
or
arrow
keys to a value specified in the table.
Sc.O…
Description
01:143_0
for the beginning of each month at midnight
02:143_0
for the beginning of each month at 6am
The daily limit "6am" (monthly limit) can be changed via
Serv.
Date and time
DayB
.
01:142_0
for the beginning of each day at midnight
02:142_0
for the beginning of each day at 6am
The daily limit 6am (monthly limit) can be changed via
Serv.
Date and time
DayB
.
01:403_0
at the beginning of every hour
Press the ENTER button to confirm the set value. It is possible to abort the entry by pressing the