Has the device time currently exceeded the parameterized point in time?
-
Does the supply to the EK280 correspond with the parametrization of the connection?
-
Is there a valid telephone number or IP address and the port of the recipient parameterized within the
associated telephone book entry?
7.5.3
Connection configuration status "StCon"
Display Description
0
Establishment of a connection has not yet started.
2
The interface is activated specifically for the connection.
3
The interface to be used for the connection (i.e. the modem) is busy, the EK280 will wait until
connection can be established.
Either the interface has just been used for another connection or the EK280 is waiting to try
again after a failed connection attempt.
This state may persist for several minutes.
4
The interface (i.e. the modem) is ready to establish a connection (i.e. the call time window is
open).
5
The interface is released specifically for the connection.
6
The interface (i.e. the modem) is released from other connections for use. (i.e. when the time
window is no longer open)
7
Data transfer via DLMS protocol is in progress.
8
Data transfer via DLMS protocol is complete.
9
Data transfer via Modbus protocol is in progress.
10
Data transfer via Modbus protocol is complete.
11
Data transfer via LIS200 protocol is in progress.
12
Data transfer via LIS200 protocol is complete.
13
The EK280 is synchronizing with the EIServer, in readiness to begin data transfer via DLMS
protocol.
14
EIServer synchronization is complete.
15
Data transfer via SMS is in progress.
19
16
Data transfer via SMS is complete.
29
No valid recipient specified.
30
A communication error occurred.
This message is shown for example, if a modem to be used has no power supply.
31
The modem's supply voltage is too low.
32
The modem cannot be used due to SIM card error (modem message: "SIM Error")
33
The modem cannot be used as an incorrect PIN has been entered.
34
The modem cannot be used as an incorrect PUK has been entered.
35
Communication link to the network cannot be established or the communication link to the
network was lost, before the communication link to the remote site could be established.
36
Communication link to the GSM network was denied.
37
The APN parameters required to establish a GPRS communication link are missing.
20
38
Communication link to APN
19
SMS only available from Software Version 2.20 or later
20
APN = "Access Point Name"