ECOMAX · Edition 02.11
21
Selection > Selection table
5 .9 .1 Type code
Code
Description
ECOMAX
Burner type
0
1
2
3
4
5
6
Burner size (max. burner output with natural gas):
0 (25 kW)
1 (36 kW)
2 (60 kW)
3 (100 kW)
4 (180 kW)
5 (250 kW)
6 (500 kW)
M
C
FTR
Recuperator: metallic
ceramic
metallic, fl at tube variant
B
D
G
L
1)
Gas type
4)
: natural gas
coke oven gas
LPG
LCV gas
395 to 695
Burner length in mm
-22 to -500
2)
Orifi ce for burner output in kW
2)
P0
3)
Gas fl ange with purging air connection
K
3)
Additional cooling air connection
A
3)
Kanthal electrode
DA1
3)
DA2
3)
Differential air pressure measuring kit
Differential air pressure measuring kit with pres-
sure switch
DW
3)
Flue gas monitoring kit with pressure switch
T
3)
NPT connection
S
3)
Spacer for SICAFLEX
®
fl ame tube
Z
3)
Special version
1)
On request.
2)
Orifi ce size on request.
3)
If “none”, this specifi cation is omitted.
4)
Other gas types on request.