Elster BK Series Operating Instructions For Operators And Installers Download Page 7

GB-7

D

GB

F

NL

I

SK

Releasing the valve

If a valve is integrated in the diaphragm gas meter 
BK, this must be released/opened for commis-
sioning.

The valve can only be released when the optical 

communication link has been established.

  1 

Establish the optical communication link, see 
[Establishing an optical communication link – p. 6].

Ensure the customer’s consumers are closed.

OFF

Opening valve

CECK IF APPLIANCES,

OFF, THEN HOLD

  2 

Release the valve.

The procedure depends on your user software.

Opening valve

Gas valve opened

Press     to continue

ON

Retrofitting/replacing the 
communication module

UMI-1

UMI-2 UMI-3

BK-Gx

12345

678

BK-Gx

123

BK-G

1

2

3

The communication module can only be retrofitted 

or replaced when the optical communication link 
has been established.

  4 

Establish the optical communication link, see 
[Establishing an optical communication link – p. 6].

The intended interface for the optional commu-

nication module is UMI-1.

  5 

The communication module and index must be 
paired.

The procedure depends on your user software.

Retrofit or replace the communication module ac-
cording to the instructions or the servicing steps 
provided by the relevant manufacturer.

  6 

Re-seal the service seal.

Check test

The MID (2004/22/EC) prescribes that the measur-

ing instrument, in this case the BK, should be able 
to be checked.

The accuracy of the meter must be checked by 

comparing the flow rates.

The requirements and test methods must comply 

with national laws and regulations.

The check should be carried out using the cyclic 

test, see [Service mode – p. 5].

Assistance in the event of 
malfunction

  ?  Fault
  !  Cause
  •  Remedy

Possible faults and suggested solutions
  ? 

The 

 symbol is displayed.

  ! 

If the 

 symbol appears next to a measured 

value, this means that the value is invalid.

  • 

After the next data synchronization, the data are 
recorded again correctly and 

 disappears.

  ? 

When pressing the user keys, the display remains 
switched off. A beep can nevertheless be heard.

  ! 

Energy-saving mode is active. If the index is used 
too often, the average energy consumption has 
been exceeded.

  • 

Do not use the index for an extended period, e.g. 
24 hours. After this, the user interface will once 
again be available.

  ? 

When pressing the user keys, the display remains 
switched off and a beep cannot be heard.

  ! 

The index is defective.

  • 

Contact the manufacturer.

  ? 

The 

 symbol is displayed.

  ! 

Low battery. This symbol is only displayed when 
battery power is low.

  • 

Change the battery.

In the case of faults which are not described here, 
contact the manufacturer immediately.

Summary of Contents for BK Series

Page 1: ... Only use OEM spare parts Transport On receipt of the product check that the delivery is complete see Part designations Report any trans port damage immediately Storage Store the product in a dry place Ambient tempera ture see Technical data Translation from the German D GB GB 1 Operating instructions for operators and installers Safety Contents Operating instructions for operators and installers ...

Page 2: ...5 Service cover 6 Service seal 7 Battery Type label Index plate BK G E DE 07 MI002 PTB001 002545632734 class 1 5 Q max Q min M10 0102 12345678 Installation Installing the gas meter For installing the gas meter in the pipe work refer to the operating instructions for diaphragm gas meters BK G1 6 to BK G25 and BK G1 6T to BK G25T see http docuthek kromschroeder com doclib main php language 1 folderi...

Page 3: ...n some menus may be missing The Current meter reading basic display appears when switching on the index If you are in a different menu the display will automatically change back to the basic display when no user key has been pressed for 30 s and switches off after a further 30 s You can navigate from the basic display to the various menus such as Meter information using the user keys Menu overview...

Page 4: ...nce between the internal time recording and the actual time is too large This can lead to invalid consumption data After the next time syn chronization the consumption data are recorded again correctly and disappears Tariff totals If the optional tariff data are configured they can be called up here Tariff data with measured gas volumes are dis played by pressing the selection key Previous tariff ...

Page 5: ...n the display 2 Briefly press the selection key A further test pattern appears in the display 3 Hold the selection key pressed down The display switches to the previous menu Cyclic test The accuracy of the meter can be checked using a cyclic volume test Cyclic test Starting Cycles 0 0 0000 00 C 00 000000m3 U 00 000000m3 Press to abandon test C volume U volume temperature converted Cycles number of...

Page 6: ...replaced when the optical communication link has been established see Establishing an optical communication link p 6 Otherwise data will be lost 2 Initiate changing the battery The procedure depends on your user software Attention The battery may only be removed once a release message has been issued by the index As soon as the release message NOW READY TO CHANGE THE BATTERY PACK appears there is ...

Page 7: ...nufacturer 6 Re seal the service seal Check test The MID 2004 22 EC prescribes that the measur ing instrument in this case the BK should be able to be checked The accuracy of the meter must be checked by comparing the flow rates The requirements and test methods must comply with national laws and regulations The check should be carried out using the cyclic test see Service mode p 5 Assistance in t...

Page 8: ... Optical interface pursuant to EN 62056 21 Mode E Annex B 2 For further technical data on diaphragm gas meters BK see Diaphragm meters BK G1 6 to BK G25 and BK G1 6T to BK G25T operating instructions http docuthek kromschroeder com doclib main php language 1 folderid 400041 by_class 2 by_ lang 1 Declaration of conformity Diaphragm gas meters BK E with electronic index We the manufacturer hereby de...