Elster Instromet Q Instruction Manual Download Page 7

 
Hexagon screws and nuts for flanges in accordance with DIN EN 1092-1 

Material / strength class 

Screw  

Nut 

Operating limits 

Standards 

5.6 5 
8.8 8 

up to 40 bar 

down to -10°C 

DIN ISO 4014 
DIN ISO 4032 

CK 35 

CK 35 

up to 100 bar 

down to -10°C 

 

DIN 2510 

Stud bolts with continuous thread for flanges  
 
in accordance with ANSI/ASME B 16.5 

Material / strength class 

Bolt  

Nut 

Operating limits 

Standards 

A 193 B6 

A 194 
Gr. 6 

up to 100 bar 
down to 0°C 

A 193 B7 

A 194 
Gr. 2H 

up to 100 bar 
down to -50°C 

 
ANSI/ASME B 1.1 

Other equivalent materials may also be used. 
 
 

7. Pulse generators 
 
LF pulse generators

 (Type IN-S) may be plugged onto the side of 

the counter cover for 

volume pulse output

 to external devices (e.g. 

a volume corrector). 

 

Fit the pulse generator (if required) as follows: 
- Slide both 

guides

 of the IN-S pulse generator into the guide slot 

on the counter cover until the guides can be heard to engage 
(clicking sound). 

- Assign the 

terminals

 on the plug in accordance with the pin 

assignment on the meter/pulse generator. 

Use a 

screened cable

 to the external device. 

 

You can use 

HF pulse generators

 for higher frequencies (Types 

A1R and A1S) (if available). HF pulse generators are screwed into 
the meter housing pressure-tight. However, the connection plug can 
be turned. 
- Assign  the 

terminals

 on the plug in accordance with the pin 

assignment on the unit. 

- Use a 

screened cable

 to the external device. 

Pulse generators for subsequent installation 

are also available. 

HF pulse generators (Type A1S) can, however, be fitted 

only by 

the After-Sales Service

. By contrast, you can connect the plug yourself, as described 

above. 

Warning!

 All pulse generators are intrinsically safe and may be connected only to 

intrinsically safe circuits

 if used in 

potentially explosive atmospheres

. The safety 

barriers must comply with the requirements of ignition protection 

EEx ib IIC

 (see also 

Marking in Annex A). 

 
 
8.

 

Pressure test point 

 
A straight male coupling in accordance with DIN 2353 is pre-fitted on the meter housing for 
connection of a pressure sensor for instance. 
The 

pressure test point

 is marked 

p

m

 and is designed for connection of d= 6 mm steel 

tube in accordance with DIN EN 10305-1 (e.g. steel grade E 235). 

All rights reserved. Subject to technical modification.  

 

Page 7 of 13 

Summary of Contents for Q

Page 1: ...Instruction Manual Turbine Gas Meter and Quantometers Type TRZ TRZ2 TRZ IFS Q ...

Page 2: ...ulse generators 7 8 Pressure test point 7 9 Temperature test points 8 10 Counter versions 9 11 Absolut ENCODER 9 12 Commissioning 10 13 Maintenance and lubrication 11 14 Care and cleaning 11 15 Recycling and environmental protection 11 16 Annex A ATEX approvals 12 17 Annex B Plastics used 13 All rights reserved Subject to technical modification Page 2 of 13 ...

Page 3: ...cation media on request This product is not intended for metering of aggressive gases e g biologically produced methane or sewage gases oxygen acetylene Turbine gas meter with volume corrector 1 Meter housing 2 Measuring cartridge 3 Counter head 4 HF pulse generator 5 LF pulse generator 6 Pressure test point with three way cock 7 Temperature test point 8 Electronic volume corrector Please contact ...

Page 4: ...ed contact HF pulse generator in accordance with DIN EN 50227 Umax 24 V Urated 8 V DC Imax 50 mA I 2 1 mA exposed I 1 2 mA covered Pmax 0 25 VA U 5 9 V exposed U 6 8 V covered Ri 100 Ω series resistor Ri 1 kΩ Absolut ENCODER S1 Encoder S1 Counter Number of digit rollers 8 Temperature range 20 C to 60 C Safety class IP 67 NAMUR II 2 G EEx ia IIC T4 or SCR II 2 G EEx ib IIB T4 or Interfaces ATEX app...

Page 5: ...ators for gas Other restrictor devices L 2D Flow conditioner e g BLN 1 L 2D No flow conditioner L 5D Flow conditioner recommended If you wish to mix in odorisation agents or use solenoid valves please always fit them only downstream of the meter Otherwise the device may be damaged The flow through the meter must be free of vibration pulsation in order to avoid measuring errors Compliance with the ...

Page 6: ...truments used provide correct results 6 Installation connection Warning Never clean the plastic cover of the counter with a dry cloth owing to the risk of explosion resulting from electrostatic discharge Please only ever use an adequately moistened cloth Before installation please ensure that the protective caps and or plastic sheeting is or are removed that the meter and accessories have been ins...

Page 7: ...d cable to the external device You can use HF pulse generators for higher frequencies Types A1R and A1S if available HF pulse generators are screwed into the meter housing pressure tight However the connection plug can be turned Assign the terminals on the plug in accordance with the pin assignment on the unit Use a screened cable to the external device Pulse generators for subsequent installation...

Page 8: ...BL ANSI 300 EBL ANSI 600 EBL GGG 50 GS GGG 45 45 80 GS 45 45 GGG 50 50 100 GS 50 50 GGG 50 50 150 GS 50 50 GS 58 58 200 St 67 GS 95 95 250 St 160 160 160 160 160 300 St 160 160 160 160 160 400 St 160 160 160 160 160 500 St 160 160 160 160 160 6 mm 600 St 160 160 160 160 160 GGG Spheroidal graphite cast iron GS Cast steel St Welded steel EBL Rounded installation length of the thermowell in mm Note ...

Page 9: ...tter unit on meters with mechanical index drive counter head version II The encoder is suitable for connection to a series connected additional device volume corrector datalogger or bus system in potentially explosive atmospheres see table Technical data A device connected to the terminal box must feature at least the following approval as a related equipment for this EEx ia IIC for version with N...

Page 10: ... our After Sales Service for such conversion work weatherproof When fitting the seals and gaskets ensure that they are aligned concentrically and do not project into the flow channel 12 Commissioning For meters without oil pump continue with point Placing the system into operation Meters with oil pump must be provided with initial lubrication Before commissioning First open the cover on the oil su...

Page 11: ...are and cleaning Clean off dirt on the meter only with a damp cloth Any media gentle on the applicable materials can be used as cleaning media Do not clean the transparent tank of the oil pump with solvent 15 Recycling and environmental protection ELSTER has reduced the transport packagings of the measuring instruments to the bare essentials Packaging materials are always selected consistently wit...

Page 12: ...EEx ia IIC T6 T4 TÜV 01 ATEX 1776 Ex marking II 2 G EEx ia IIC T4 Premagas s r o 91601 Stará Turá Slovakia Elster GmbH 55252 Mainz Kastel Germany Inductive proximity switch N 95000 PTB 01 ATEX 2192 Ex marking II 1 G EEx ia IIC T6 IFM Electronic GmbH 45127 Essen Germany HF pulse generators A1 R A1 S Inductive proximity switches NJ 1 5 10 GM N NJ 1 5 8 GM N old version Both versions with identical e...

Page 13: ...breviation Chem name Pulse generators PA 6 6 Polyamide Flow bodies PAMXD6 Polyarylamide Gears and small parts POM Polyoxymethylene Counter cover and counter PC Polycarbonate Counter bottom section PPA Polyphthalamide Digit rollers PA 12 PPO Polyamide Polyphenylene oxide All rights reserved Subject to technical modification Page 13 of 13 ...

Reviews: