Installation
, connection and commissioning
33
Press the ENTER
+
button to confirm the set value. It is possible to abort the entry
by pressing the key combination ESC
+
.
Move the cursor with the arrow keys
or
further to the gas analysis values (Ho.b,
CO2, etc.).
Change the values in accordance with the gas used by enabling with the ENTER
+
key combination the entry, going with the arrow keys
or
to the figures and changing
them with the keys
or
.
Press the ENTER
+
button to confirm the set value. It is possible to abort the entry
by pressing the key combination ESC
+
.
5.3.1.8 Setting the alarm limits for gas pressure and temperature measurement
Ex works, the alarm thresholds are set to sensible values. If a change is necessary, proceed
as follows:
Move the cursor to the "Serv" tab and via the following paths to the alarm thresholds:
Serv.
Measured values
Pressure
pMin
and
pMax
9
Serv.
Measured values
Temperature
TMin
and
TMax
Press the key combination ENTER
+
to enable the entry.
Move the cursor with the arrow buttons
or
to the digits and change these with the
arrow buttons
or
.
Press the ENTER
+
button to confirm the set value. It is possible to abort the entry
by pressing the key combination ESC
+
.
5.3.1.9 Setting replacement values for gas pressure and temperature
If the gas pressure or the gas temperature cannot be measured due to a fault or if pressure
and temperature are outside the alarm limits defined in chapter 5.3.1.8, an adjustable
replacement value (fixed value) is used to calculate the standard volume. The volume
thereby calculated is counted in the separate fault volume meter VbD (Base Volume
Disturbed).
The total base volume counter VbT is keep on counting although there is a disturbance. The
total base volume calculated under these faulty conditions has no measuring relevance. It
must not be used for billing purposes.
The replacement values can be found at the following paths:
Serv.
Measured values
Pressure
p.F
10
Serv.
Measured values
Temperature
T.F
The values are changed as a rule in the same way as described in chapter 5.3.1.8.
5.3.1.10 Parameterization of the outputs
The setting of the cp values (pulse constants) for the outputs can be carried out
via the enSuite software as an alternative.
The following functions are preset for the outputs as factory settings:
9
These values are not required in the performance as Temperature Conversion device.
10
These values are not required in the performance as Temperature Conversion device.
Summary of Contents for EK205
Page 1: ...Operating manual Volume conversion device EK205 ...
Page 6: ......
Page 64: ...64 Appendix 9 2 Conformity declarations19 19 IECEx is not available for all device types ...
Page 65: ...Appendix 65 9 3 Design test certifications 9 3 1 ATEX EC Type Examination Certificat ...
Page 66: ...66 Appendix ...
Page 67: ...Appendix 67 ...
Page 68: ...68 Appendix 9 3 2 IECEx Certificate of Conformity20 20 Not available for all device types ...
Page 69: ...Appendix 69 ...
Page 70: ...70 Appendix ...
Page 71: ...Appendix 71 ...