P03/3 Weather Station
2
P03/3 Weather Station
• Version: 07.06.2021 • Technical changes and errors excepted. • Elsner Elektronik GmbH • Sohlengrund 16 • 75395 Ostelsheim • Germany • www.elsner-elektronik.de •
Technical Service: +49 (0) 7033 / 30945-250
so as
not to pull off the wire
connecting the PCB in the bottom part with the rain
sensor in the cover (wire with push-connector).
Push the connecting cable through the rubber seal on the bottom of the weather
station and connect the power and data cables to the terminals provided for this
purpose. The supply cable to the weather station should be a maximum of 30 m
long. The connection is by typical telephone cable (J-Y(ST)Y 2 × 2 × 0.8).
The connection cable must be plugged in between the cover and circuit board.
2.2.4. PCB Layout
Set jumper:
Please reboot the system after the setting of the jumper!
2.2.5. Mounting the sensor
Close the housing by putting the cover back over the bottom part. The cover must
snap in on the left and right with a definite “click”.
To remove it, the sensor can be simply pulled upwards out of the mount, against
the resistance of the fastening.
2.3. Notes on mounting and commissioning
Do not open weather station if water (rain) might ingress: even some drops might
damage the electronic system.
Observe the correct connections. Incorrect connections may destroy the weather
station or connected electronic devices.
Please take care not to damage the temperature sensor (small blank at the bottom
part of the housing.) when mounting the weather station. Please also take care not
to break away or bend the cable connection between the blank and the rain sensor
when connecting the weather station.
Remove all existing protection labels after installation.
The correct wind value may only be supplied about 30 seconds after the supply
voltage has been connected.
2.4. Maintenance of the weather station
WARNING!
Risk of injury caused by components moved automatically!
The automatic control can start system components and place people
in danger.
•
Always isolate the device from the mains for servicing and
cleaning.
The device must regularly be checked for dirt twice a year and cleaned if necessary.
In case of severe dirt, the sensor may not work properly anymore.
ATTENTION
The device can be damaged if water penetrates the housing.
•
Do not clean with high pressure cleaners or steam jets.
3.
Disposal
After use, the device must be disposed of or recycled in accordance with the legal
regulations. Do not dispose of it with the household waste!
Control model
Jumper position
WS1000 Touch
no jumper
All other models up to production year 2001
jumper at position (a)
All other models from production year 2002 on
jumper at position (b)
Fig. 12: Overview PCB
1 Socket for connect-
ing cables to
rain sensor in hous-
ing cover
2 Connection plug
1: +24 V DC | 2: GND |
3: Data (massive ca-
ble up to 0.8 mm²)
3 Control LED GPS re-
ceiver
4 Socket for jumper
1
2
3
4
a
b
Fig. 13
Make sure the cover and bottom part
are properly snapped together! This
picture is looking at the closed sensor
from underneath.
Fastening
Fig. 14
Push the housing from above into the
fastened mount. The bumps on the
mount must snap into the rails in the
housing.
Fig. 15
After installation, remove the "distan-
ce" sticker on the top of the cover.