background image

Radio motor control unit RF-MSG-ST IP54

2

Radio motor control unit RF-MSG-ST IP54

 • Version: 08.06.2020 • Technical changes and errors excepted. • Elsner Elektronik GmbH • Sohlengrund 16 • 75395 Ostelsheim • Germany • www.elsner-elektronik.de • 

Technical Service: +49 (0) 7033 / 30945-250

2.3.1. Connection scheme

2.4. Establish wireless connection

1. Set the control unit and/or remote control or the button to teaching mode (obser-

ve the corresponding manual/data sheet)

2. Switch on the 

RF-MSG-ST IP54

 voltage supply or interrupt it for at least 3 se-

conds  if the unit is already supplied with power.

3. For 5 minutes after connecting the voltage, the 

RF-MSG-ST IP54

 will send a "Le-

arn" telegram every 10 seconds.

4. The wireless connection will be established automatically. For building control 

systems, the display will display "Device is learning".

5. The 

RF-MSG-ST IP54

 will stop sending "Learn" telegrams once the reply "Lear-

ned" (for a learning process) or a control command is received (in the event of a 
power interruption during operation).

2.5. Notes on mounting and commissioning

Device must not be exposed to water (rain). This could result in the electronics being
damaged. A relative air humidity of 95% must not be exceeded. Avoid condensati-
on.

3.

Disposal

After use, the device must be disposed of or recycled in accordance with the legal
regulations. Do not dispose of it with the household waste!

1 Neutral conductor
2 L
3 nc (not connected)
PE

Motor output

STAK3 coupling for
STAS3 plug

Input mains voltage

STAS3 slot for 
STAK3 coupling

1 Neutral conductor
2 Up
3 Down
PE  

Fig. 2

PE

PE