29
KNX Interface for WS1000
• Status: 15.04.2016 • Errors excepted. Subject to technical changes.
2.5.4. Functional blocks
Blocks with 7 objects
The menu point appears only if the option that blocks with 7 objects should be used
has been selected with "Functional blocks".
The data for awnings, blinds, shutters, windows and Elsner electronic ceiling fans
WL305/610 is transmitted with the help of these 22 blocks. The blocks are also suitable
for light, dimmers, buttons, 3-way combination sensors (temperature, humidity and
CO2), thermal hygrometer, temperature sensors and floating point values.
In "Functional Blocks", the option selected is:
Sending behaviour of safety objects
• on change
• on change to 1
• on change to 0
• on change and periodically
• on change to 1 and periodically
• on change to 0 and periodically
Transmit cycle
(only if "periodically" is selected)
5 s • 10 s • 30 s • 1 min • … • 2 h
Use blocks with 7 objects
No • Yes
Use blocks with 3 objects
No • Yes
Use blocks with 2 objects
No • Yes
Use blocks with 1 object
No • Yes
Use blocks with 7 objects
Yes
Block 7_1
… Block 7_22
• Do not use
• Output: Blind
• Output: Awning
• Output: Shutters
• Output: Windows
• Output: Sliding window
• Output: Step window
• Output: Light switchable
• Output: Light dimmable
• Input: Up/down key
• Input: On/Off key
• Input: Temperature
• Input: Temperature, humidity
• Input: Temperature, humidity, CO2
• Input: 2 byte floating point
• Input: 4 byte floating point
• Fan WL305/610