![Elsema MD240-2 Manual Download Page 3](http://html1.mh-extra.com/html/elsema/md240-2/md240-2_manual_2396484003.webp)
ELSEMA
MD240-2 Vehicle Loop Detector
- 3 -
Dip switch Settings
1 and 2 of CH1
Function
Automatic Reset (Both Channels)
Dip switch
2 is ON
Vehicle can be permanently present. (no auto-reset, unless vehicle
has left or manual reset)
Dip switch
2 is OFF
Normal mode, (automatic reset after 10minutes present of vehicle,
used to solve the mistake operation. If it is recommended).
Dip switch Settings
3 of CH1
Function
Special Functions
Dip switch
3 is ON
Direction Detection. (If vehicle moves from CH1 to CH2, then
CH1 relay output; if vehicle moves from CH2 to CH1, then CH2
relay output).
Dip switch
3 is OFF
Normal mode, two loop detection are separated.
Dip switch Settings
4 of CH1
Function
Special Functions
Dip switch
4 is OFF
CH1 relay will be present output.
Dip switch
4 is ON
CH1 relay output type is pulse.