iS260/iS260D
SWING
GATE
OPENER
MANUAL
1.3 TECHNICAL FEATURES:
B Dimension:
1.4 MAINTENANCE
:
Maintenance should be performed at least every six months. If it is used in high traffic area, a
more regular maintenance should be performed.
Disconnect the power supply
:
(1)
Clean and lubricate the screws, the pins and the hinge with grease.
(2)
Check the fastening points are properly tightened.
(3)
Check and make sure that the wire connections are in good condition.
Connect the power supply
:
(1) Check the power adjustments.
(2) Check the function of the manual release
(3) Check the photocells or other safety device.
Motor Voltage
24Volts DC motor
Gear Type Worm gear
Nominal Thrust 2000N
Stroke Length (CD) 400mm
Power Supply 240 Volts AC
Nominal Input Current 2 Amps
Maximum Operating Current 4.2 Amps for maximum 10 sec
Maximum Gate Weight 200 kg per leaf
Maximum Gate Length 2.5 metres
Duty Cycle 20%
Operating Temperature -20°c ~ +50°c
Dimension 819mm x 197mm x 100mm
7