USER MANUAL
EL SERIES
04.04.2018
33
times; this message indicates that the
sensor are reading different heights.
2/2
Function Locked-Armguard
During descent, the controller can stop
movement for a configurable time, to
alllow a safety check that no -one is
close to the machine.
The operatör must release and then re-
select DOWN to continue lowering (after
the delay timeout). If armguard feature is
not wanted, set the armguard height
%101. This procedure should perform
with the firm.
1/1
Not Calibrated
Height and load based functions are
required, but height and/or load has
not been calibrated.
Calibrate load which includes height
calibration.
This
procedure
should
perform with the firm.
2/2
Function Locked- External Shoutdown
An external shutdown is preventing
functions.
Check the SYSTEM/MODE/INTERLOCK
to see which external interlock is active.
This procedure should perform with the
firm.
2/2
Function Locked-Overloaded
The platform is loaded too high to allow
operation.
The platform load must be reduced.
2/2
Funtion Locked-Underloaded
Platform overload features are active,
and the platform load is too low to be
valid.
This could be caused by erroneous
calibration, a sensor fault, or a change in
the machine mechanics/hydraulics. This
procedure should perform with the firm.
2/2
Function Locked-Too High
The platform is raised too high to allow
some functions.
This procedure should perform with the
firm.
2/2
Function Locked-Tilted
The machine is tilted too much to allow
some function.
This procedure should perform with the
firm.
7/7
B+ Stud Voltage too Low
Check the power wiring for errors.