background image

Indicator

PCB Position

PCB Board

Dip Switches

‘TEST MODE – WALK TEST’ is displayed.   

Press             to activate Walk Test.    

 ‘ Walk Test Waiting…’

  is displayed.  Press the ‘ARM’ button 

on the Remote Control;   Alarm Panel will beep and the type of the device and button will be on the 

display. Press the other buttons on the Remote, as each button is pressed the Alarm Panel will beep 

and show the button being pressed on the display. KEEP THE ALARM PANEL IN THE TEST MODE! 

PIR Motion Sensor:  

PIR Sensors are designed to detect movement. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Insert the 9 Volt battery. The PIR will warm-up during 2-3 minutes. The LED will flash. When it is ready 

the LED stops. First check the house code: SW2; switch 1 – 8 (must be same as Remote Control). You 

can divide your detectors over your total home in zones. You can set the alarm zone the PIR detector 

will operate on, by switch the dip switches 1, 2 and 3 (of SW3; dipswitch 1-5) in the position according 

schedule above. Mark which zone number on the PIR. For walk test mode you put dip 4 of SW3 On. 

Don’t forget to put back in Off. Test the PIR in the walk test mode. In normal mode the PIR will only send 

a mew signal after being triggered after 2 minutes 

The PIR sensor incorporates an anti-false alarm for where the Sensor might be affected by e.g. insects, 

air temperature etc. We recommend high sensitivity, but in case of affection of (e.c. insects) , you can 

adjust dip 5 of SW3 to Off: low sensitivity detection!  

 

Door/window magnet: 

The Magnetic Contact consists of two parts; a Detector and a Magnet.  They are designed to be fitted 

to doors or windows with the Magnet mounted on the moving/opening part.  

 

 

 

 

 

 

 

 

 

Mounting the door/wind magnet: 

Decide which doors/windows are to be protected by fitting Magnetic  

Contact Detectors, (usually the front and back doors. Additional detectors   

may also be fitted where required to other vulnerable doors or windows,  

(e.g. garage, patio/conservatory doors etc).Ensure that the position selected  

for the Magnetic Contact detector is within effective range of the Control Panel, (refer to  

‘Testing the Control Panel & Remote Control’). Remove the battery holder, and mount the  

detector using either the adhesive tape or screws. Fit the Magnet to the moving part of the door/window 

opposite the Detector. Ensure that the parallel gap between the Magnet and Detector is less than 10mm 

and that the arrow on the Magnet is pointing towards and aligned with the mark on the Detector. 

Mounting the PIR motion sensor: 

Household pets should not be allowed into an area protected by a PIR detector! Do not locate the 

detector facing a window facing direct  sunlight.  PIR Detectors are not suitable for use in 

conservatories. Do not locate the detector where it is exposed to ventilators. Do not locate the detector 

 

DIP 1 

DIP 2 

DIP 3 

Zone 1 

OFF 

OFF 

OFF 

Zone 2 

OFF 

OFF 

ON 

Zone 3 

OFF 

ON 

OFF 

Zone 4 

OFF 

ON 

ON 

Zone 5 

ON 

OFF 

OFF 

Zone 6 

ON 

OFF 

ON 

O

E

1     2     3     

Open the sensor, take out the battery 
connector, and place the battery! Check the 
house code; same as PIR and Remote Dip 1-
8 from 1-12. Select the Zone you want: setting 
Dip 9-11 according the overview at the PIR. 
Mark the Zone number on the magnet. 

Summary of Contents for Pro Alarm System AP5500

Page 1: ......

Page 2: ...ELRO 10 Zone Pro Alarm System with Voice and Digital Dialer AP5500 Position planning ...

Page 3: ...e Garage PARM1 but not the rest If we are a sleep we only arm the Garage and down floors PARM2 but not the rest If we are away from home Full armed We also can give a sensor being defined as an sensor with Exit Entry Delay For example If we leave home and we want to switch on the alarm on the panel we give the door window magnet E the Exit Entry delay status All other sensors can have the immediat...

Page 4: ... to be used then the Control Panel will need connecting to a convenient telephone point Route the cable from the Power Supply Unit up behind connect the plug to the DC power socket in the panel Take care that during installation and testing on the table the sabotage switch and the back stays free Now set the Alarm panel in programming mode by pressing 1 USER SETUP is displayed Remote Control The R...

Page 5: ...tact consists of two parts a Detector and a Magnet They are designed to be fitted to doors or windows with the Magnet mounted on the moving opening part Mounting the door wind magnet Decide which doors windows are to be protected by fitting Magnetic Contact Detectors usually the front and back doors Additional detectors may also be fitted where required to other vulnerable doors or windows e g gar...

Page 6: ...stall mode Press until you see in the display DISARM READY and the time Now we go into the Program Install mode mentioned further Inst mode Press 1 2 3 4 1 2 3 4 standard Master Password display show 1 USER SETUP First we will change the Master Password Press 1 1 USER 1 SETUP Press display 1 7 MASTER SETUP Press display 1 Password 1234 Press display Enter Password Code NOW PRESS YOUR NEW CODE and ...

Page 7: ... Press to insert a 3 6s pause in the dialing sequence Press to move the cursor left Press to move the cursor right Press to delete the character under the cursor Press and hold to erase the entire phone number Scroll through the menu until 4 3 RECORD VOICE is displayed and press Scroll through the available menu options until the required message type to be recorded is displayed 1 Main Alarm messa...

Page 8: ...ill always be points to improve points Which these are nobody can tell us no better then you We would like to hear from you what your experience was during the preparation installation and the use of this ELRO 10 ZONE PRO ALARM SYSTEM Go to www elro eu and give us your opinion about this ELRO 10 ZONE PRO ALARM SYSTEM Wishes and tips are very welcome You will also find an overview of accessories an...