Technical Manual Milk Cooling Controller TARN 1600

Page 3

  Functional Description

Applications

The TARN 1600 is a combined controller, which
controls temperature by switching a solenoid
valve or a compressor and a stirrer, which is
necessary for milk cooling/storage applications.

Temperature Display

The measured temperature value (

P01

) can be

read on the display with a resolution of 1K or 0,1K
(selectable by 

P09

). The display is also able to

show °C or °F (

P10

).

Different temperature sensor types can be used:
TF 101, TF 201 and  TF 501 (Pt1000), selectable
by 

P08

. Please note that they have different

temperature ranges.

Min/Max (Peak Value) Memory

The controller always stores the highest and the
lowest measured temperature value, which can
be read by the 

"

×

"

 and 

"

Ø

"

 keys (see page 1).

Sensor Correction

In case of display deviation (e.g. sensor position,
deviation by cable lenght, etc.), the display can be
corrected by parameter 

P07

.

Temperature Controller

The temperature controller works as follows:
• Cooling ON

(Cooling relay activared = Compressor ON):
Actual Value > (Setpoint P02 + Hysteresis P03)

• Cooling OFF

(Cooling relay de-activared = Compressor OFF):
Actual Value < Setpoint P02

An adjustable switching hysteresis prevents from
short switching cycles 

(P03)

.

Depending on the mounting position of the sensor,
sensor type and its mass, control deviations may
occur which are wider than the set hysteresis.

Stirrer Control

After power-up of the controller, the stirrer switches
ON delayed by 

P14, 

if no cooling is necessary.

While normal operation, the stirrer relay is always
activated with the cooling relay. After the cooling
relay has been switched OFF, the stirrer trails for
the time set by 

P06. 

After that, the stirrer operates

with the ON/OFF-times set by 

P05

/

P06

.

The stirrer can also be started and stopped
manually (see page 1).

Temperature Alarm

A temperature alarm is forwarded by:
• a LED on the front
• by an integrated beeper
• by an alarm relay

When the measured temperature leaves the range
set by 

P12

 / 

P13

, a delay timer (

P11

)

 

starts. After

this timer has been run down, a temperature
alarm will be generated.
By pressing any key, the alarm is reset for about
10 minutes. While this time, the alarm LED flashes.
After the end of this period, the alarm is repeated.
If the temperature comes back to the normal
range, alarm relay, beeper and LED are reset
automatically.

warm

activated

de-activated

cold

se

tp

oi

nt

hy

st

er

es

is

 

CONNECTION INFORMATION & SAFETY INSTRUCTIONS

Please read before Start-up

The guarantee will lapse in case of damage caused by failure to
comply with these operating instructions! We shall not be liable for
any consequent loss! We do not accept liability for personal injury
or damage to property caused by inadequate handling or non-
observance of the safety instructions! The guarantee will lapse in
such cases. Cleaning: The use of a dry, lint-free cloth is sufficient to
clean the product.

If you notice any damage, the product may not be connected to
mains voltage! Danger of Life!

A riskless operation is impossible if
• The device has visible damages
• The device doesn't work
• After a long-time storage under unfavorable conditions
• After inadequate shipping 

conditions

• Limit of Application: This product is not designed nor

manufactured for use in equipment or systems that are
intended to be used under such circumstances that may
affect human life. For applications requiring extremely high
reliability, please contact the manufacturer first.

The product may only be used for the described
applications.

• Electrical installation and putting into service must be

done from authorized personnel.

• Please note the local safety instructions and standards !
• Before installation: Check the limits of the controller and

your application. Before starting up we recommend you to
read the manual for use, since only by doing so you can
avoid damage or malfunction and you will benefit all the
advantages offered by this product.

During installation and wiring never work when the
electricity is not cut-off !

Never operate unit without housing.

• Connect the ‘PE’ terminal carefully to ground because

otherwise the operation of the internal noise filter will be
disabled.

• Mounting the controller close to power relays is

unfavourable in case of the electro-magnetic interference.

• Before applying voltage to the controller:

Make sure that all wiring has been made in accordance
with the wiring diagram in this manual.
Check, if the supply voltage corresponds to the value
printed on the type label.

• Respect the environmental limits for temperature and

humidity. Outside these limits malfunctions may occur.

• Observe the maximum admitted current rate for the

relays

 

(see technical data). Compare with the peak start-

up current of the controlled devices (fan, compressor,etc.)

• Use shielded cable for sensor elongation only. Don’t install

them in parallel with high-current cables to prevent inductive
interference. A wire gauge of min. 0,5mm² is sufficient.

• Shielding must be connected to PE at the end near the

controller

• All used temperature sensors must be identical. Never

different sensor types mixed. This will not work.

• TF-type sensors are not designed for being immersed in

fluids for a long period of time (not pressure-proof). In such
a case, always use dip-fittings.