5. Functions
The operator controls the pump with the start- and stop switches on the handle. When the start-
switch is pushed, the pump motor starts and a hydraulic pressure is built up in hose and crimp-
tool. When a preset max pressure is reached, the system is automatically unloaded and tool
retracts. This procedure is often called a crimp cycle. A crimp cycle can be interrupted, by
releasing the start-switch, restarted again by pushing start-switch or ended, by pushing the stop-
switch at any time. If foot pedal is used, start and stop function is the same.
The ERGOCOM use wireless communication, bluetooth, and is available for PS710E.
Each handle is coded to a certain pump from safety aspects. The pump ID No is marked on the
handle.
The ERGO handle is the version with wired communication useable for PS710R.
Start of pump.
Always attach a crimp tool to the hose in depressurised state and connect the
handle to the tool.
This is for personal safety, never run the pump without tool, crimping or cutting tool.
1.
Set main switch in position ”off”
2.
Connect the mains cord plug to a 100-240 VAC power outlet with protective earth, PE
3.
Set main switch in position ”on”
4.
Press stop switch on the handle to activate the electronic self check, (PS710E and PS710D)
Change of tool accessories should only be done with main switch in position “0”
When pump is not used, always set main switch in position “0” and disconnect power cable.
For longer stops, tool should be disconnected from hydraulic hose and hose from pump.
Battery should preferable be kept in dry environmental when not in use.
Before charging Li-ion battery, the separate charger instruction must be read.
In the electronic control system for PS710E and PS710D every crimp characteristic with the crimp
Id-No is saved. All the crimps can be analyzed afterwards or on-line in real-time by using the
Elpress Analyser software in a separate PC, connected to the pump with USB. This give a unique
opportunity for quality check
.
If the pump memory is full and crimps are not to be transferred to an external PC the pump
memory can be deleted by use of the “Clear logs” function in the main menu.