ALC Outdoor LF BUS Beacon – Installation Guide
www.elpas.com
Page 5 of 12
V11/March 2015
Door Primary – Secondary Placement (without loop)
A primary/secondary configuration may be installed by mounting the primary and secondary beacons on opposite sides of the door, at
a height of 1.2m/4Ft above the floor
.
The resulting LF fields are automatically synchronized in real time to avoid problems associated
with coverage area overlap.
Corridor Primary – Secondary Placement (without loop)
A primary/secondary configuration may be installed by mounting the primary and secondary beacons on opposite sides of the
corridor, at a height of 1.2m/4Ft above the floor
.
The result is a uniform LF field between them that provides full coverage.
Note:
In the primary beacon, there is no need to set the bottom Mode Selection DIP switch.
Note:
For a primary with two secondary beacons configuration, contact Elpas Support.