read
Function
Read data from the device.
Syntax
/read
[[x] y]
The optional argument
x
specifies the data source; if
x
is missing, a card will be
read. Refer to the Read Argument table below for a description data sources.
The optional argument
y
is used to specify a message to be displayed on the
LCD screen, if supported, before carrying out the command. If
y
is omitted
and the device supports a display, the text in the
msg1
property is shown. In
order to use
y
, the
x
argument must be present. See the
display
command
for the description of the message format for
y
.
Errors
/read
-00045
<LF>
If a command is already pending or the
enc_key
is not defined for
read pin
.
/read
-00082
<LF>
If the command was canceled by the application (82) or by the user (83) (e.g.,
with CLEAR key).
Remarks
The response to this command has the following format:
/read
status data
The
status
field is a 6-character string aligned to the right in the arg1 field. It is
formatted as follows:
TX
1
X
2
X
3
SS
T
defines the type of data that was read:
C
= a check was read
M
= a magnetic card was read
P
= a PIN was read
K
= a key press or string was read
-
= indeterminate: no data was received from the device. Returned on errors
not specific to the data type, such as command canceled (SS=
82
).
X
i
define a media-specific status. For checks, this is the decimal representation of
the check read status, as defined in the MICR specification. For magnetic cards,
XXX indicates the read status for each of the three magnetic tracks (see
card
in
the Read Arguments table below for a description of the status). For PIN data
this status is always
000
; for keypress and string data,
XXX
is the data length in
characters.
SS is a two-digit status code.
00
indicates a good read (but some tracks may be
bad); any other status code indicates an error. These error codes indicate an error
in the communication between the driver and the device or driver’s internal
errors. Read errors are reported in the X
i
fields and do not cause the SS field to
be set to a non-zero value. See Appendix C. Status Codes.
The
data
format is described in the
write
command below.
Example
To request an amount to be entered by the customer on the IntelliPIN:
Command
/set entry_len 6
<LF>
/read key_string Enter the amount
<LF>
Response
/read
K00300 123
<LF>
Example
To read a card (from any device):
Command
/read card
<LF>
Response
/read
M10900 ;12345?
<LF>
track 1 error, track 2 good, track 3 blank
Summary of Contents for Entuitive 1525L Series
Page 8: ...2 5 Side View Base Bottom View User Controls ...
Page 27: ...2 24 E l o E n t u i t i v e T o u c h m o n i t o r U s e r G u i d e ...
Page 31: ...3 28 E l o E n t u i t i v e T o u c h m o n i t o r U s e r G u i d e ...
Page 44: ...C 41 See Detail A Detail A ...
Page 45: ...C 42 E l o E n t u i t i v e T o u c h m o n i t o r U s e r G u i d e ...
Page 48: ...45 N10051 ...
Page 49: ...46 E l o E n t u i t i v e T o u c h m o n i t o r U s e r G u i d e ...
Page 59: ...56 Figure 1 1 USB Swipe Reader ...
Page 63: ...USB Swipe Reader 60 ...
Page 67: ...USB Swipe Reader 64 ...
Page 69: ...USB Swipe Reader 66 ...
Page 117: ...MagTek Device Drivers for Windows 114 ...
Page 127: ...MagTek Device Drivers for Windows 124 ...
Page 141: ...MagTek Device Drivers for Windows 138 ...
Page 163: ...MagTek Device Drivers for Windows 160 ...
Page 165: ...MagTek Device Drivers for Windows 162 ...