Introduction 

RS-232  is  the  interface  with  asymmetric  signals.  Maximum  load  capacity  can  be 

2500pF and equates to c.50m typical twisted-pair cable.  

The  asymmetric  signals  are  not  ideal  to  eliminate  the  influence  of  zero  potential 

differences of terminal equipments (TE and/or DTE). The TE and neutral potentials 

have  to  be  the  same  hence  the  RS-232  interface  is  intended  to  the  point-to-point 

connection for 15m distance. 

The load impedance is to be 3-7 kilo-ohm that allows disturbing pulses to induce 

into the cable even from the soft supplies. 

 

1.1 

Use of the converter 

Current  loop  interface  is  resistant  to  electromagnetic  interference 

but  not  to 

atmospheric electricity influences!

   

The current loop enables to span the metallic link of the resistance up to 500 Ohm 

using the power supply of 12 V. 

 

2.0 

Operation principles 

E00X converts TxD signal into the transmitting cable pair of the current loop and 

the signal from the receiving pair into the RxD thus the full duplex connection is 

carried  out.  In  the  idle  mode  the  20mA  current  flows  through  each  current  loop. 

The maximum transmission rate is 115 200 bps. Control signals are not transmitted. 

 

3.0 

Installation 

There  are  two  different  problems  of  installation  to  discuss:  the  converter  and  the 

TE connection via the RS-232 interface and two modems interconnection. 

 

3.1 

RS-232 interface connection 

The DB9F (Female) connector is used to the converter connection. The connector 

is  connected  as  the  DCE  (to  the  end  device  connector,  the  converter  can  be 

connected  directly  or  via  the  cable  1:1).  Signals  assignment  to  the  contacts  and 

signals´ direction is in the following table: 

Summary of Contents for ELO E00X

Page 1: ...RS 232 Miniature Converter to Current Loop ELO E00X Operation manual ...

Page 2: ...Operation principles 3 3 0 Installation 3 3 1 RS 232 interface connection 3 3 2 Two Modems interconnection 4 3 3 Power Supply Connection 5 4 0 Specifications 5 4 1 Parameters 5 4 2 Other 6 5 0 Testing 6 5 1 Auto test 6 6 0 Troubleshooting 7 7 0 Ordering Information 7 ...

Page 3: ...nables to span the metallic link of the resistance up to 500 Ohm using the power supply of 12 V 2 0 Operation principles E00X converts TxD signal into the transmitting cable pair of the current loop and the signal from the receiving pair into the RxD thus the full duplex connection is carried out In the idle mode the 20mA current flows through each current loop The maximum transmission rate is 115...

Page 4: ...ach loop the twisted pair should be applied to limit the radiation and particularly the disturbance from outside Each loop connects one transmitter to one receiver and has to contain a power supply The transmitter or receiver supplies this power most often it is so called active transmitter or receiver whereas the passive receiver is a consumer and the passive transmitter is a current switch that ...

Page 5: ...r on the converter case or via 8 positive or 4 negative contacts on the current loop connector The power supply of 12V 100mA is used most often E0Q4 type The power supply voltage may be of maximum 24V for one supplied current loop thus up to 50mA 4 0 Specifications 4 1 Parameters RS 232 interface DCE RS 232 connector DB9F Current loop interface transmitter and receiver active passive Current loop ...

Page 6: ...s 5 0 Testing If interconnected properly both diodes light up on each modem Any simple communication test can be used terminal emulator 5 1 Auto test You can test either single converter or connected to the terminal equipment with the external supply of 12 24 V The DB9M connector contacts are interconnected via two jumpers 7 2 and 9 1 Both diodes must be alight The transmitted sign has to appear i...

Page 7: ...k if both diodes light after installation Check the power supply Check RS 232 connection Connection in normal Check the power supply operation quit working Check the cable connection Use auto test and find out if the converter is OK 7 0 Ordering Information Supply code is ELO E00X ...

Page 8: ...ELOE00XZKE001 8 ...

Reviews: