Elo TouchSystems E221 User Manual Download Page 13

ELO E221ZKE001

4.0 Testing

Plug the adapter to the Ethernet network. Power up the adapter. 

After a second should light up an orange indicator LNK (close to 
the Ethernet socket).. In a minute should LNK indicator (orange) 
light on. If not, the cable may be defective or improper wired (when 
connecting to the endpoint like PC – you should use cross-over UTP 
cable, in other cases use straight UTP cable) or power supply is not 
good or module might be damaged. In a while the green indicator 
ACT starts blinking indicating a network traffic. Make sure drivers 
are   installed   (see   chap.   3.5).   Start  

DigiWiz.

  application   from 

supplied CD-ROM and click “

Next

” to discover the adapter. If it 

appears   in   the   window,   installation   was   successful.   Finish   the 

DigiWiz application (

click “

Next

”). See the port number in Device 

Manager. Connect loopback to the RS232 port (connecting Tx and 
Rx together) and run the 

Autotest 

application from the installation 

CD-ROM. Fill up the port number and click “

Start data transfer

”. If 

everything   is   O.K,   the   message   “Data   transfered   successfully” 
appears; while if not, the error message “Timeout on Device Read” 
will be seen.

For testing purpose can be helpful a HyperTerminal, which is part 

of the operating system MS Windows.

12

Summary of Contents for E221

Page 1: ...Communication adapter RS232 over the Ethernet ELO E221 User manual...

Page 2: ...4 3 2 RS 232 connection 4 3 3 Power supply 5 3 4 Driver installation 5 3 5 Virtual COM port installation 5 3 6 Virtual Port settings 8 3 7 Uninstalling the adapter drivers 8 3 8 Adapter configuration...

Page 3: ...pplied software allows setting up following profiles 1 Real Port profile Adapter allows to connect a device with RS232 interface straight to computer via Ethernet protocol with virtual port applicatio...

Page 4: ...d 100Mbps 3 0 Installation This chapter describes the adapter E221 installation process The process is divided to sub process software and hardware installation 3 1 Ethernet connection Adapter meets I...

Page 5: ...change 3 4 Driver installation The adapter s configuration software can operate on computers under Operation systems both MS Windows and Linux Unix but only Windows software is enclosed Supported are...

Page 6: ...the Digi device Setup Wizard screen will appear Click Next 3 On the next screen Discover Device the adapter with IP and MAC address should be seen If not check power cabling and DHCP service and click...

Page 7: ...ntually corrected by clicking Next To acknowledge click Next 8 On the screen Save settings is saved configuration and started installation of Serial adapter Digi Connect ME and COM port Digi Connect M...

Page 8: ...drivers Driver can be uninstalled in Device Manager caption Multiport serial adapter right click on device Digi connect Wi ME in menu select Uninstall After this procedure the devices Digi connect ME...

Page 9: ...l too 4 A Network section contains IP Settings IP address assignment Network Services Settings offers some network services Advanced Network Settings other settings Every settings change must be confi...

Page 10: ...ged user approved to login and configure the adapter and assigned different rights for every user 11 A Management section shows active configuration and allows some changes to that It depends on chose...

Page 11: ...ide of a serial bridge A bridge connects two serial devices over the network as if they were connected with a serial cable so called Serial tunnelling As it it commonly used configuration installation...

Page 12: ...Digi device server 6 Local Configuration the Local Configuration Profile allows you to connect standard terminals or terminal emulation programs to the serial port in order to use the serial port as...

Page 13: ...a network traffic Make sure drivers are installed see chap 3 5 Start DigiWiz application from supplied CD ROM and click Next to discover the adapter If it appears in the window installation was succes...

Page 14: ...thing works but serial connection Check a serial cable Check if the serial port installed in Device Manager Check adapter configuration especially serial interface 6 0 Ordering info Ordering code is E...

Page 15: ...2 interface Connector DB9 male Transmission speed max 230 kb s Transmitted signals TXD RXD RTS CTS DTR DSR DCD Flow control HW or SW Xon Xoff GPIO general I O with RS232 voltage levels 12V Others Conf...

Page 16: ...ELO E221ZKE001 15...

Reviews: