4.- CLEANING AND MAINTENANCE 

Disconnect the heater for your safety before cleaning your applicance and make sure the heater is cool before 
continuing. 
Clean and dust with a dry, soft cloth only when the unit is disconnected and cold.   
Do not use solvents or abrasive products for cleaning. 
This  thermal  radiator  has  been  manufactured  under  an  assured  quality  system  using  environment  friendly 
processes. 
Please take the heater to a clean point once their useful life is finished, in order to recycle their materials in the 
right way. 

Warning: 

When the appliance is not operated for a long period of time, cleaning or maintenance is conducted 

or when the location of the heater is changed, the heater should be turned OFF and unplugged from the electrical 
connection. 

5.- TROUBLESHOOTING 

E1 Error on display 

Control Unit Overheat. Check installation clearances. Let heater cool for 15 minutes 
and restart heater. 

No heat when L1,2,3   

Bulb is damaged. Contact Technical Service. 

o 4 shown on display 

6.- THECNICAL DATA. ERP PRODUCT FICHE 

 

Model 

IFC-2000 

Power 

2000 W 

Power Levels 

4 levels (2000 / 1600 / 1200 / 800 W) 

Voltage 

220 

 240 V

 

Weight 

3 kg 

Dimensions 

90 x 13 x 9 cm 

IP Code 

IP55 

Remote Control 

Yes 

24h Programmable 

Yes 

Heating Element 

Carbon Heating Lamp 

 

Information 

Symbol  IFC-2000 

Unit 

Item 

Value 

Heat Output

 

Type of heat output / room temperature control 

Nominal heat output 

P

nom 

2.0 

kW 

Electronic control plus daily timer 

Yes 

Minimum heat output 

P

min 

0.8 

kW 

Maximum continuous heat output 

P

max,c 

2.0 

kW 

Other Control Options

 

Auxiliary electricity consumption

 

With working time limitation 

Yes

 

At nominal heat output 

el

max 

0.000 

kW 

At minimum heat output 

el

min 

0.000 

kW 

With black bulb sensor 

Yes 

In standby mode 

el

SB 

<0.0005 

kW 

 

Contact details 

ELNUR, S.A.   
Travesía de Villa Esther, 11 
28110 

 Algete (Madrid), Spain 

 

Commission Regulation (UE) 2015/1188 of 28 April 2015. Ecodesign requirements for electric radiant local space heater.

 

 

Summary of Contents for Gabarron IFC-2000

Page 1: ...INFRARROJO DE CARBONO CARBON INFRARED HEATER WALL CEILING MOUNTING MONTAJE MURAL O TECHO IFC 2000 Lea estas instrucciones atentamente antes de instalar o utilizar el aparato por primera vez Please read these instructions CAREFULLY before installing or using this appliance for the first time ...

Page 2: ...ther the connecting cable nor any other object must come into contact with the heater This heater should be switched off at the isolating switch before any repair work is carried out The installation must be carried out in accordance with the current electrical regulations The heater should not be installed just below an electrical socket outlet or dripping clothes The heater is to be installed so...

Page 3: ...e components of the heater or replace the components with the ones that do not meet the safety requirements WARNING The surface of this heater can be hot Parts of the heater may exceed 200ºC CAUTION Some parts of this product can become very hot and cause burns Particular attention must be given when children and vulnerable people are present WARNING IN ORDER TO AVOID OVERHEATING DO NOT COVER THE ...

Page 4: ...bellow than 1 8m from the floor Consideration should be given to any temporary or occasional additions such as stages or platforms and adjusted accordingly For outdoor use or other areas with air movement wind the directional infrared spread may reduce by 1 3 to 1 2 Wall ceiling installation swivel brackets are provided with the heater which has been specifically designed to allow this product to ...

Page 5: ...hange the batteries in the same way described above Warning 1 Replace the old batteries with the same type batteries Otherwise your heater may not function well 2 Pull out the batteries in case of long terms of disuse to prevent leakage which may impair your remote control 3 Do not allow water or liquid to get into the remote control Timer Adjustment Press Timer button 5 and use the Up and Down bu...

Page 6: ...t heater cool for 15 minutes and restart heater No heat when L1 2 3 Bulb is damaged ContactTechnical Service o 4 shown on display 6 THECNICAL DATA ERP PRODUCT FICHE Model IFC 2000 Power 2000 W Power Levels 4 levels 2000 1600 1200 800 W Voltage 220 240V Weight 3 kg Dimensions 90 x 13 x 9 cm IP Code IP55 Remote Control Yes 24h Programmable Yes Heating Element Carbon Heating Lamp Information Symbol I...

Page 7: ...iador No deje cable colgando del extremo de mesas o escalones ni deje que entre en contacto con cualquier superficie caliente No utilice el radiador mientras duerma Nunca deje el radiador desatendido mientras esté en funcionamiento Un manejo inadecuado puede causar heridas graves No utilice alargadores de cable Esto puede causar sobrecalentamiento y causar un incendio No deje ningún objeto encima ...

Page 8: ...apagar el radiador Nunca desmonte los componentes del radiador ni los reemplace por otros que no cumplan los requisitos de seguridad ADVERTENCIA La superficie de este aparato puede estar caliente Algunas partes del equipo pueden llegar a 200ºC PRECAUCIÓN Algunas partes del aparato pueden estar muy calientes y causar quemaduras Se debe prestar particular atención en presencia de niños y personas vu...

Page 9: ... ninguna circunstancia instale el IFC 2000 por debajo de 1 8metros sobre el suelo Para uso en exteriores u otras áreas con movimiento de aire la propagación del efecto del infrarrojo puede reducirse de 1 3 a 1 2 Un juego de soportes giratorios para la instalación en la pared techo se suministran con el calefactor Éstos han sido diseñados específicamente para permitir que el producto se instale en ...

Page 10: ... y polaridad de las mismas 2 Reemplace las baterías siguiendo el mismo procedimiento descrito arriba Advertencias 1 Reemplace las baterías con el mismo tipo De otra manera el equipo no funcionará correctamente 2 Extraiga las baterías en caso de largos periodos de no uso para prevenir posibles pérdidas que pudieran dañar su mando a distancia 3 No permita que agua u otros líquidos penetren en su man...

Page 11: ... se emite calor con La lámpara puede estar dañada Contacte con el servicio técnico L1 2 3 o 4 en display 6 INFORMACIÓNTÉCNICA FICHA ERP Modelo IFC 2000 Potencia 2000W Niveles de Potencia 4 niveles 2000 1600 1200 800W Tensión de alimentación 220 240V Peso 3 kg Dimensiones 90 x 13 x 9 cm Grado IP IP55 Mando a Distancia Sí Programable 24h Sí Elemento Calefactor Lampara de Carbono Información Símbolo ...

Page 12: ...herwise be caused by inappropriate waste handling of this product For more detailed information about recycling of this product please contact your local city office your household waste disposal service or the shop where you purchased the product These instructions are only valid in the EU member states El símbolo en el producto o en su embalaje indica que este producto no se puede tratar como de...

Reviews: