background image

 

INSTRUCCIONES DE USO 
USER OPERATING INSTRUCTIONS 
 

ACUMULADOR DE CALOR INTELIGENTE 
INSTALACIONES DE AUTOCONSUMO CON 
VERTIDO DE EXCEDENTES A RED 
 
SMART STORAGE HEATER 
PV INSTALLATIONS WITH PHOTOVOLTAIC 
SURPLUS PRODUCTION 
 

ECOMBI SOLAR 

 

MODELOS / MODELS 

ECO15 SOLAR 
ECO20 SOLAR 
ECO30 SOLAR 
ECO40 SOLAR

 

 

Por favor, lea estas instrucciones atentamente antes de instalar o utilizar el aparato por primera vez. 

Please read these instructions carefully before installing or using this appliance for the first time. 

 

Summary of Contents for ECO15 SOLAR

Page 1: ...STORAGE HEATER PV INSTALLATIONS WITH PHOTOVOLTAIC SURPLUS PRODUCTION ECOMBI SOLAR MODELOS MODELS ECO15 SOLAR ECO20 SOLAR ECO30 SOLAR ECO40 SOLAR Por favor lea estas instrucciones atentamente antes de...

Page 2: ...or un electricista cualificado antes de volver a utilizarlo Para desconectar el aparato ponga el interruptor en la posici n apagado y desconecte del cuadro de protecci n de la vivienda No inserte ni p...

Page 3: ...as diferentes opciones disponibles ENCENDIDO APAGADO Una vez que el acumulador est conectado al suministro el ctrico accione el interruptor general situado en la parte posterior derecha del acumulador...

Page 4: ...e consigna deseada El asistente inicial de instalaci n dejar el equipo configurado para su funcionamiento aut nomo sin la funci n de aprovechamiento de excedentes Cargar y acumular el calor durante la...

Page 5: ...y adicionalmente cargar hasta el nivel definido en el par metro Carga M xima en Valle en el tramo de carga definido o Solar Valle Corregida Ecombi Solar cargar y almacenar energ a siempre que haya exc...

Page 6: ...do en dicho modo hasta que se muestre la temperatura deseada La temperatura de consigna y el nivel de carga se muestran en pantalla en este modo AJUSTAR TEMPERATURA DE CONSIGNA Programa semanal La tem...

Page 7: ...a verano y viceversa incluso si no est conectada a la centralita G Control siempre que el par metro Cambio de Hora Autom tico est activado Activado por defecto de f brica 3 3 Editar programa Este men...

Page 8: ...rados en el equipo Programa 1 En casa De Lunes a Domingo 00 00 07 00 Eco 07 00 22 00 Confort 22 00 00 00 Eco Programa 2 Trabajo L V De Lunes a Viernes 00 00 07 00 Eco 07 00 08 00 Confort 08 00 17 00 E...

Page 9: ...a configurado los diferentes tramos horarios del d a que hab amos seleccionado pulse y la configuraci n de ese d a se quedar grabada COPIA DE LA PROGRAMACI N DE UN D A AVANCE AL D A SIGUIENTE Puede co...

Page 10: ...el men de Ajustes Avanzados Ver secci n 3 5 Ajustes Avanzados 3 4 2 D as de carga en la semana Es posible seleccionar los d as de la semana que el acumulador Ecombi solar cargar y cu les no Acceda al...

Page 11: ...la Claro B N fondo blanco y letras negras Oscuro N B fondo negro y letras blancas Color pantalla de inicio con los iconos a color 3 5 2 Ajustes de funcionamiento RESISTENCIA COMPENSACI N o Estado Acti...

Page 12: ...eratura 2 C 2 C UP10 Unidades de temperatura C C UP11 Funci n Ventanas Abiertas Off Off UP12 Funci n Puesta en Marcha Adaptable Off Off UP13 Tipo de Control de Temperatura PID PID UP14 Restricci n com...

Page 13: ...r y configurar las diferentes funciones del acumulador a trav s de la app Elnur Gabarron Wifi Control o a trav s de la app web https remotecontrol elnur es 5 PROBLEMAS Y SOLUCIONES ECOMBI Solar no cal...

Page 14: ...o funcionar n nunca al mismo tiempo ES ADVERTENCIA Para evitar sobrecalentamientos no cubrir el aparato de calefacci n ES i i ECO15 Solar ECO20 Solar ECO30 Solar ECO40 Solar Largo 55cm 66cm 89cm 111cm...

Page 15: ...ss than 8 years shall not plug in regulate and clean the appliance or perform user maintenance Children of less than 3 years should be kept away unless continuously supervised Do not operate any heate...

Page 16: ...ess the key to decrease the displayed value or to move through the different options available ON OFF Once the heater is connected to a main supply you can turn the heater ON by switching the main ON...

Page 17: ...hoice With the help of the start wizard you will set you Ecombi Solar storage heater for an autonomous operation It will charge and store the heat during the charging hours set in c Charging Periods a...

Page 18: ...he Off peak period You can set the off peak maximum charge using the corresponding option o Solar and Grid Adjustment Ecombi Solar will charge and store energy whenever there is surplus It will also c...

Page 19: ...layed The setpoint temperature and the charge level are displayed on the screen in this mode ADJUST SETPOINT TEMPERATURE Weekly programme The setpoint temperature varies in accordance with the weekly...

Page 20: ...t connected to the G Control hub provided that the Automatic Time Change parameter is activated Activated by factory setting 3 3 Programme Settings This menu will only be accessible when the device is...

Page 21: ...set in the device Programme 1 At home Monday to Sunday 00 00 07 00 Eco 07 00 22 00 Comfort 22 00 00 00 Eco Programme 2 Work M F Monday to Friday 00 00 07 00 Eco 07 00 08 00 Comfort 08 00 17 00 Eco 17...

Page 22: ...Comfort Press to go to the next hour When you have set the different hourly periods for the day selected press and the setting for this day will be recorded COPY THE DAILY PROGRAMME GO TO THE NEXT DAY...

Page 23: ...3 4 2 Charging days in the week It is possible to select the days of the week on which the Ecombi Solar heater will charge and those on which it will not Access the Charging Days menu and select the d...

Page 24: ...ight B W white background and black letters Dark B W black background and white letters Colour Home screen with coloured icons 3 5 2 Operating settings BLANCING HEATING ELEMENT o Status Balancing heat...

Page 25: ...Max Balancing element working period 5 hours 3 hours UP09 Overtemperature protection 2 C 2 C UP10 Temperature Unit C C UP11 Open Window Detection Function Off Off UP12 Adaptive Start Control Off Off U...

Page 26: ...e settings of your storage heater using the Elnur Gabarron Wifi Control app or the app web https remotecontrol elnur es 5 TROUBLESHOOTING ECOMBI SOLAR does not heat Please check it is connected and sw...

Page 27: ...y Limiter Ref 15192140 8 THECNICHAL FEATURES Storage heater elements and balancing heating element will never operate at the same time EN i i ECO15 Solar ECO20 Solar ECO30 Solar ECO40 Solar Connection...

Page 28: ...in previo aviso As a part of the policy of continuous product improvement Elnur UK Ltd reserves the right to alter specifications without notice ELNUR S A Traves a de Villa Esther 11 28110 Algete Madr...

Reviews: