Switch on the voltage again.
•
As soon as the blue LED lights up (about 0.5 sec. after power on) press and hold immediately the setup
pushbutton.
•
The blue LED goes o
ff
. After about 10 sec the blue LED and the red LED light up together.
•
Release the setup button. All parameters are set to delivery condition.
Update der Firmware
The firmware of the
ElMod FusionX
is done through the
ElMod App
. The newest firmware versions are always
included in the current installation package of the
ElMod App
. A new version of the
ElMod App
may be
installed anytime. It's not necessary to deinstall the existing version before.
For updating the firmware the
ElMod FusionX
must be connected to a computer. To set the PCB in update
mode, switch o
ff
the voltage and press and hold the setup pushbutton on the
ElMod FusionX
. Switch the
voltage on again. The blue status LED blinks three times. Now start the
ElMod App
and press the red
"Update" button. Follow the instructions on the screen.
Additional information
A number of further articles about the
ElMod FusionX
can be found in our knowledge
database in the service area at
or by scan of the QR code.
SAFETY INSTRUCTIONS
General
- Damage caused by non-observance of these operating instructions will void the warranty! We assume no liability for
consequential damages!
- We accept no liability for damage to property or personal injury caused by improper handling or non-compliance with the
safety instructions! In such cases all warranty claims are void.
- For safety and approval reasons (CE), unauthorized modification or conversion of the device is not permitted. Only use
original spare parts or equivalent spare parts for repairs.
- Make sure that all electrical connections and connections have been made correctly and in accordance with these
operating instructions.
- If the ambient climate changes suddenly (e.g. from a cold room to a warm room), moisture can condense on the unit
and possibly destroy it. Do not operate the unit until it has been acclimatized for about 2 hours.
- Do not operate the device in the vicinity of easily inflammable objects, liquids or gases, danger of explosion!
- Do not expose the device to high temperatures, strong vibrations, high humidity or chemically aggressive environments.
- Operate the device only in a dry environment (below 80 % humidity, non-condensing) and at normal room temperature.
- Do not operate the unit unattended.
- If you have any questions about the operation, safety or connection of the device that are not explained in the operating
instructions, please contact your dealer's support or another specialist.
Electrical hazards
- Supply the device only with low voltage as specified in the technical data. Only use current sources approved for model
making, such as NiMh rechargeable batteries. Operation with voltages higher than 11.1V is not permitted. There is a fire
hazard!
- Observe the limit values for currents as specified in the technical data. Exceeding the permissible values leads to
overloading and destruction of the device and carries the risk of fire or electric shock.
- Installation and connection must only be carried out when the device is disconnected from the power supply.
- Ensure that all connecting cables have a sufficient cross-section.
- -
11