- 3 -

HOW TO USE

1. Adjust the iris and focus of the lens so that optimum image

may be obtained.
* Usable lenses

CS-mount lenses, whose length "L" (in the illustration)
from the bearing surface of the mount is 4mm or less if
protruded, should be used.

* Using the zoom lens (adjustment of the back focus)

The camera is set at the standard back focus position when
shipped from factory. Depending on types of zoom lenses,
however, slight readjustment may be necessary.
Adjust the lens back-focus by turning the focusing dial in
either direction as per the illustration, referring to the following instructions.

Place an object at any fixed distance and set the focus ring of the zoom lens accordingly.
Set the zoom lens to full TELE position and obtain the best focus position by turning the 
focus ring or the zoom lens.
Set the zoom lens to full WIDE position and obtain the best focus position by turning the 
focusing dial located on the side of the camera.
Repeat procedures 2 and 3 until focus remains constant throughout the zooming range.

Note: When weight of the lens is more than 1kg (2.2lbs), the camera should be supported by the

lens rather than relying on camera mounting screw.
Adjust the back-focus only when necessary.

4

3

2

1

Lens

CS-mount

4mm or less

L

Camera

Lens

Focusing dial

* Using an auto iris lens
When a DC driven type auto iris lens is used, set the AUTO IRIS switch at DC, and connect the
plug of the lens (for iris terminal) to the IRIS terminal on the right side of the camera.
When a video feedback type auto iris lens is used, set the AUTO IRIS switch at VIDEO, and
connect the plug of the lens (for iris terminal) to the IRIS terminal on the right side of the
camera. (Refer to Lens manual for the level adjustment.)

* When a video feedback type auto iris lens (peak/average selectable type) is used at peak

mode, BLC may not function well. In such a case, select the average mode.

2. Before your use of the camera at AES (Automatic Electronic Shutter) mode.

* When using an auto-iris lens, set the AES switch at OFF.

(The AES switch is set at OFF when shipped from factory.)

* The AES mode may increase smears on monitors, which is caused by characteristics of CCD

and is not defect.

Set the AES switch at OFF in case smears appear excessively.

VIDEO position

+9V iris power (50mA Max.)

GND

0.8Vp-p auto iris video signal

GND

DC position

Control -

C

Drive +

Drive - (GND)

1
2
3
4

IRIS terminal

Plug for IRIS terminal

(CHUOMUSEN E4-191J-150)       Soldering side

Summary of Contents for TEB4404

Page 1: ...LECTRIC SHOCK DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE The CAUTION label is attached on the bottom of camera INFORMATION This equipment has been tested and found to comply with the limits for Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial envir...

Page 2: ...r added protection for this video product during a lightning storm or when it is left unattended and unused for long periods of time unplug it from the wall outlet and disconnect the power supply and cable system This will prevent damage to the video product due to lightning and power line surges 13 Overloading Do not overload power supply and extension cords as this can result in a risk of fire o...

Page 3: ...nd wire of the power supply cord Camera control switches Refer to CAMERA CONTROLS on page 4 8 7 1 2 DC12V AC24V All dimensions in mm inch HOW TO CONNECT 1 Before connection make sure that power of all units are OFF and cords are unplugged 2 Mount a lens onto the camera Refer to HOW TO USE for usable lens 3 Connect video terminal of the camera and the video input terminal of a monitor TV etc with a...

Page 4: ... the lens rather than relying on camera mounting screw Adjust the back focus only when necessary 4 3 2 1 Lens CS mount 4mm or less L Camera Lens Focusing dial Using an auto iris lens When a DC driven type auto iris lens is used set the AUTO IRIS switch at DC and connect the plug of the lens for iris terminal to the IRIS terminal on the right side of the camera When a video feedback type auto iris ...

Page 5: ...witcher to a monitor TV the vertical sync phase can be locked with the power frequency and a stable vertical sync is obtained without being disturbed at the time of switching Caution 1 The camera is synchronized to the power frequency of 60Hz 0 5Hz covering a normal fluctuation of the power frequency The camera may not compensate for large fluctuation caused by power generated by an engine generat...

Page 6: ... at the position fully counterclockwise that the delay time of vertical sync phase against the phase of power frequency is shortest when shipped from the factory Turning this potentiometer clockwise will make the delay time of vertical sync Phase against the phase of power frequency longer Use the function control potentiometer if the picture image on a monitor TV may flow when using the camera in...

Page 7: ...aced Scanning frequency H V 15 734kHz 60Hz Sync system Internal Line lock Internal Resolution 570 TV lines Horizontal 350 TV lines Vertical Recommended illumination 10 lx F1 2 under incandescent lamp AGC Built in Factory set at ON Gamma selecter Yes Backlight control Built in AES Built in Factory set at OFF Automatic Electronic Shutter Output signal VBS 1 0 Vp p 75Ω NTSC compatible Auto iris termi...

Page 8: ...urs relocate cables or reinstall equipment Check the ambient temperature and humidity Avoid using camera in areas where temperature is consistently hotter or colder than the specified range See Specifications chart below or poor image quality or damaged parts may occur Precautions should also be taken to avoid areas of high humidity Should you notice any trouble If any trouble occurs while you are...

Reviews: