![Elmo SN2230 IP II Instruction Manual Download Page 15](http://html1.mh-extra.com/html/elmo/sn2230-ip-ii/sn2230-ip-ii_instruction-manual_2394658015.webp)
- 14 -
5. Alarm
The alarm operation is enabled only when the multi-cable is in connection.
(For the details of connection, refer to the instruction manual of the multi-cable.)
Alarms are caused by “alarm 1”, “alarm 2”, and “motion detection”.
You can set an alarm action for each cause. “With/Without alarm”, “Send e-mail/Send
FTP/Both/None” are available.
Note:
An alarm remains output from the alarm output terminal for ten
seconds. The alarm output period is fixed.
Specifications of the alarm output terminal: Open collector output,
maximum rating: DC12 V, 30 mA
Note:
The next alarm input can work normally three seconds after the
current alarm is input. If the alarm input is active again within three
seconds, the alarm input may not work normally depending on the
equipment status.
Connected
to
network
None
Alarm input 1
(non-voltage make contact input)
Motion detected
Code
Signal
name
color
Brown
Alarm input 1
Red GND
Alarm input 2
(non-voltage make contact input)
Code
Signal
name
color
Orange
Alarm input 2
Yellow GND
Alarm output
(open collector output)
Code
Signal
name
color
Green Alarm
output
Camera
Multi-cable
Ethernet cable
Alarm
IN-OUT terminal
Input
Output
Send e-mail
(See page 35, 36
for setting)
Send FTP
(See page 37, 38
for setting)
Both
(See page 35, 36,
37 and 38 for setting)