Gold DC Whistle Installation Guide
MAN-G-DCWHIIG-EC (Ver. 1.705)
||The Gold DC Whistle Connection Diagram|
21
Chapter 6:
Wiring
Once the product is mounted, you are ready to wire the device. Proper wiring, grounding and
shielding are essential for ensuring safe, immune and optimal servo performance of the drive.
The following table legend describes the wiring symbols detailed in all installation guides.
Wiring Symbol
Description
Earth connection (PE)
Protective Earth Connection
Common at the Controller
Shielded cable with drain wire.
The drain wire is a non-insulated wire
that is in direct contact with the braid
(shielding).
Shielded cable with drain wire
significantly simplifies the wiring and
earthing.
Shielded cable braid only, without drain
wire.
Twisted-pair wires
Encoder Earthing.
The cable`s shield is connected to the
chassis (PE) in the connector.
Earthing the Encoder and connecting the
Earth (PE) to the drive COMRET is
mandatory to insure reliable operation,
high noise immunity and rejection of
voltage common mode interferences.