background image

  

 

Product identification 

  

  

© Gardner Denver Deutschland GmbH 

15 

32 

02.2017 · 610.00181.40.000 

  

 

EC/EU declaration of conformity 

  

Manufacturer:

  

Gardner Denver Deutschland GmbH 
Industriestraße 26, 97616 Bad Neustadt, Germany 

  

Representative for the 
compilation of technical 
documents:

  

Holger Krause, Gardner Denver Deutschland GmbH 
Industriestraße 26, 97616 Bad Neustadt, Germany 

Designation of the ma-
chine:

  

Vacuum Pump  

 

Series F-CEVF 

 

 

Types F-CEVF 

3718-3(29) 

F-CEVF 3718-
3(A002) F-CEVF 
3718-3(31) F-CEVF 
3718-3(45) F-CEVF 
3718-3(55) F-CEVF 
3718-3(90)  

F-CEVF 3718-4(29) 
F-CEVF 3718-
4(A002)  

 

The manufacturer bears sole responsibility for issuing this declaration of compliance. The machine 
described above complies with all applicable harmonisation legislation of the Community:

  

2006/42/EC

  

Directive 2006/42/EC of the European Parliament and of the Council of 17 
May 2006 on machinery, and amending Directive 95/16/EC 

harmonised standards and other technical specifications on which the declaration of compliance is 
based:

  

EN 1012-1:2010

  

Compressors and vacuum pumps - Safety requirements - Part 1: Compres-
sors 

EN 1012-2:1996 +A1:2009

  

Compressors and vacuum pumps - Safety requirements - Part 2: Vacuum 
pumps 

EN ISO 12100:2010

  

Safety of machinery - General principles for design - Risk assessment and 
risk reduction (ISO 12100:2010) 

EN 60204-1:2006/ A1:2009/ 
AC:2010

  

Safety of machinery; electrical equipment for machinery part 1: General 
requirements IEC 60204-1:2005 (amended) 

EN 60034-1:2010/ AC:2010

   Rotating electrical machines - Part 1: Rating and performance IEC 60034-

1:2010 (amended) 

Signed for and on behalf of: Gardner Denver Deutschland GmbH 

Bad Neustadt,16.02.2017 

(Place and date of issue)

  

  

664.00181.40.000 

 

3.4 

Summary of Contents for F-CEVF 3718-3(29)

Page 1: ...Edition 02 2017 610 00181 40 000 Original operating instructions English Operating instructions F CEVF 3718 3 29 A002 31 45 55 90 F CEVF 3718 4 29 A002...

Page 2: ...aration of conformity 15 4 Transportation and storage 16 4 1 Unpacking and checking the condition of delivery 16 4 2 Lifting and transporting 16 4 3 Storage 17 5 Mounting 18 5 1 Measures after long te...

Page 3: ...1 2 Fitting dimensions for hose 28 12 2 Permitted conditions for use 28 12 2 1 Installation height 28 12 2 2 Rotational speeds 28 12 2 3 Temperatures 28 12 2 4 Pressure differences 29 12 2 5 Relative...

Page 4: ...leshooting Maintenance repairs and spare parts Decommissioning Technical data The main section on Safety and responsibility must always be observed The subsequent main sections can be used as a refere...

Page 5: ...rigid When the lowest normal frequency of the system consisting of the F CEVF and substructure is less than 25 above the rotary frequency of the F CEVF per measurement direction then the substructure...

Page 6: ...ion 01 2016 Explanation of the terms and symbols 4 Safety and responsibility 7 Rating plate 12 Design of the machine 13 EC EU declaration of conformity 15 General installation regulations 20 deleted C...

Page 7: ...acuuming up materials that fall into printing machines The CEVF 29 A002 and 45 may be used to vacuum up paper powder and dusts The CEVF 31 55 and 90 may be used to vacuum up paper or foil in the form...

Page 8: ...ndition 1 Switch off and disconnect from the power supply 2 Wait for impeller and external fan to stop 3 Secure to prevent it from being switched back on 4 Make sure that it is de energised 5 Earth it...

Page 9: ...g Fitter Safe handling of tools Laying and connecting pipes and hoses Mounting mechanical components Knowledge of suction blowers Working on the electri cal system Electrician Understanding and safe i...

Page 10: ...n wear head protection for transportation and overhead work WARNING Risk of injury Serious injuries due to body parts and hair being sucked or drawn in vacu um or due to projected particles pressure 1...

Page 11: ...not exceeded The operator ensures that All work on the F CEVF is carried out by personnel that have the necessary Staff qualifications and training 9 personnel that have been sufficiently informed of...

Page 12: ...erations C Serial number year of manufacture L Volume flow D Machine type protection class thermal class M Manufacturer s recommendations optional E Frequency N Customer information optional F1 Maximu...

Page 13: ...e clamp on top 0020 Filter body 0409 Quick release clamp on bottom 0040 Connection cable 0500 Motor protection circuit breaker 0042 Junction box 2000 Rating plate 0062 Feet 5190 Adhesive label with di...

Page 14: ...a gas inlet item N1 0 13 The drive and the fan form a single unit A shaft seal is arranged between the storage chamber and the compression cham ber The impellers are overhung and are located on the e...

Page 15: ...of the Community 2006 42 EC Directive 2006 42 EC of the European Parliament and of the Council of 17 May 2006 on machinery and amending Directive 95 16 EC harmonised standards and other technical spec...

Page 16: ...ispose of packaging material in accordance with the valid local regulations Lifting and transporting Transportation by crane WARNING Danger of crushing and cutting Danger of crushing and cutting of bo...

Page 17: ...ll openings so that no dirt or solid particles can enter 2 Avoid storage for more than 6 months 3 Adhere to storage and standstill conditions Storage and standstill condi tions Permitted values Ambien...

Page 18: ...losed spaces ensure that there is sufficient ventilation For conveyed media other than air leaks from the F CEVF must be taken into account e g forced ventilation gas monitoring No exhaust air from ot...

Page 19: ...flow through the F CEVF external drive through conveyed media install a check valve if neces sary WARNING Risk of injury due to uncased gas inlet Severe injuries to body parts drawing in of hair Opera...

Page 20: ...variation in voltage with a loss of performance according to EN 60034 1 range A for IE3 motors 2 deviation in frequency The electrical data are provided on the rating plate item M 12 The electrical in...

Page 21: ...00 Controls Controls and instruments must be constructed and arranged in such a way that They are easily visible and accessible and can also be operated without ex cessive effort The operator understa...

Page 22: ...di agram in the junction box item 0042 13 or motor protection circuit breaker item 0500 13 and the following figures M4 0 8 1 2 Nm 0 60 0 90 ft lbs M5 1 8 2 5 Nm 1 35 1 85 ft lbs 9 If available conne...

Page 23: ...screws connecting elements and electrical connections are fixed at the given tightening torques Do the operating conditions match the data plate details given above Have all protection measures been c...

Page 24: ...o suction conveyed media Switch off 1 Switch off current supply The F CEVF interrupts the suction of the conveyed media The pressure will be slowly reduced The F CEVF slowly shuts down 2 If fitted clo...

Page 25: ...ct system Fitter Impeller grinds or rotor is jammed Open F CEVF remove foreign objects clean or replace parts Service Suction power too low Incorrect direction of rotation Check 23 the direction of ro...

Page 26: ...st be adjust ed by the user as necessary Maintenance interval Maintenance measure To be car ried out by Depending on the con centration of contami nant particles daily to monthly Checking and emptying...

Page 27: ...ections that are open 4 Loosen the F CEVF from the installation surface 5 Store 17 or dispose of 27 F CEVF Disposal WARNING Burns chemical burns or poisoning Risk of injury due to contact with residua...

Page 28: ...31 55 90 2x 40 2x 1 57 For further dimensions see dimensional drawing Permitted conditions for use Any deviations from the following permissible operating conditions must be agreed with the manufactu...

Page 29: ...space of the F CEVF Minimum distances Adhere to the following minimum intervals for removing and installing the filter bags item 0405 13 the filter cartridge item 0405 13 and for dissipating the heat...

Page 30: ...st code ISO 2151 with reference to the basic standard ISO 3744 Measured at a distance of 1 m for 70 pmax and connected supply lines tolerance 3 dB A Type 50 Hz 60 Hz dB A dB A F CEVF 3718 3 29 A002 45...

Page 31: ......

Page 32: ......

Reviews: