Elmes Electronic ST100HS Instruction Manual Download Page 2

e-mail: 

[email protected]

    internet: 

www.elmes.pl

 

Elmes Elektronik 12.2015. All rights reserved.

  

 

Installation

 

The  control  units  should  be  installed  with  230VAC  wiring  terminals  in  upwards  direction  and  white  antenna  wire  let 
loose downwards (not glued or fitted to wall).  External directional antenna may be screwed to antenna terminals and 
the white antenna wire removed. Screening of external antenna coaxial cable should be connected to ground terminal 
while signal wire to A terminal. Care should be taken not to expose the control unit to harsh environmental conditions 
such as very low/high temperatures or high humidity. Two screws are provided for fitting the control unit to wall. 

Description of ST..H control unit 230VAC wiring terminals: 

L

  - 230VAC mains supply 

LIVE 

wire terminal, 

N

  - 230VAC mains supply 

NEUTRAL

 wire terminal, 

PE

 - 230VAC mains supply 

GROUND 

wire terminal,  

PE

 

- electric motor 

Ground

 wire terminal,  

OPEN

  - electric motor 

LIVE 

wire terminal (

opening rotation

), 

middle 

- electric motor 

Neutral 

wire terminal, 

CLOSE

 - electric motor 

LIVE 

wire terminal (

closing rotation

), 

 

- courtesy/warning 230VAC lamp 

LIVE 

terminal. 

ST..H wire control terminals (NO ANY VOLTAGE ALLOWED!) 

COM 

- common wiring terminal, 

OP 

- wired wall switch terminal - opening rotation, 

CL 

- wired wall switch terminal 

– closing rotation, 

RS

 

- reset photo/infrared barrier beam terminal. 

Must be wire 

shorted to COM terminal if barrier is not fitted. 

 

 

Specification 

  mains supply 230VAC (2VA) control panel with superheterodyne receiver for 433,92MHz band,  

  relay outputs for motor control, 2 x NO, max 16A/250VAC, 

  courtesy/warning control relay output : max 5A/250VAC, 

  infrared obstacle detection barrier NC type (normally closed), 

  electric motor operation time range (opening and closing) 1s 

 4 min, 

  programmable PAUSE time: 1s 

 4 min, 

  control panel external dimensions (l/w/h) 87/87/39mm,

 

  open field maximal operating range: up to 100m for ST100H set and up to 200m for ST200H set.

 

 
 
Manufacturer 

 
ELMES ELECTRONIC, 54-

611 Wrocław – PL, ul. Avicenny 2, tel. (+48) 71-784-59-61, fax (+48) 71-784-59-63 

 

Manufacturer’s Limited Warranty:

   

Elmes Electronic remote control sets carry two 

year manufacturer’s warranty as from date of purchase. The warranty is 

limited  to  the  replacement  of  faulty  original  parts  or  repair  defects  of  improper  manufacture.  Damage,  faulty  use  or 
improper handling by the user or installer as well as any changes in product’s hardware or software caused by the user 
violets the warranty and all due repair costs will be charged. Elmes Electronic shall not be responsible for any damage 
human or material caused by its products failure to operate correctly.   
 

 
 
 
Elmes Electronic reserves the right to change product specification without prior notice.  

KEELOQ

®

 is a registered trademark of Microchip Technology Inc., USA. 

WARNING! Control unit and electric motor connection to 
230VAC mains voltage require personal safety care pro-
cedures  to  be  taken  and  mains  voltage  line  be  in  off 
state at installation. 

IMPORTANT!  230VAC  supply  LIVE  wire  must  be  con-
nected  to  L  terminal  and  NEUTRAL  wire  must  be  con-
nected to N terminal. 

Reviews: