background image

General 

 

4

 

BA_S50R_EN_Vers.08.2011 

© Elma GmbH & Co KG

  

 

 

General 

The present Operating Instructions are part of the delivered 
equipment. They must be ready for use at any time and remain 
with the unit in case of resale.  
We reserve the right to carry out technical modifications on the 
unit due to advanced development. 

Important safety warnings 

Please observe any additional national safety regulations that 
may apply. 

2.1 

Instructions for the use of the present manual 

Carefully read the Operating Instructions before you operate the 
unit. Do not use the present electrical unit for any purpose other 
than described in the Operating Instructions. 

Warning symbols used in the present manual: 

This symbol warns of the risk of injury caused by electricity. 

This symbol warns of the risk of injury caused by explosion 
and/or deflagration. 

This symbol warns of the risk of injury caused by hot surfaces 
and liquids. 

This symbol warns of the risk of injury. 

 

This symbol warns of the risk of damage to the equipment. 

 

This symbol marks additional information. 

 

Signal words used in the present manual 

The signal word Danger warns of a potential risk of serious 
injury and danger to life. 

The signal word Warning warns of the risk of serious injury and 
heavy damage to the equipment. 

The signal word Caution warns of the risk of light injury or 
damage to the equipment. 

The signal word Attention warns of the risk of damage to the 
equipment. 

 

 

 

 

 

 

 

 

Danger 

Warning 

Caution 

Attention 

Summary of Contents for Elmasonic S50R

Page 1: ...lpingstr 1 7 D 78224 Singen Tel 49 0 7731 882 0 Fax 49 0 7731 882 266 info elma ultrasonic com www elma ultrasonic com document ref 105 9842 Operating Instructions Elmasonic S50R Lab Technology Ultras...

Page 2: ...gassing 11 4 8 2 Sieve holder for laboratory sieves 11 4 8 3 Stainless steel basket 13 4 8 4 Plastic cover with orifice 13 4 9 Operating and display functions 15 5 Initial operation 17 5 1 Connecting...

Page 3: ...s 08 2011 3 9 Maintenance 27 9 1 Maintenance Care 27 9 2 Service life of the transducer tank 27 9 3 Repair 28 10 Technical details 29 11 Troubleshooting 30 12 Putting out of action and waste disposal...

Page 4: ...ng Instructions Warning symbols used in the present manual This symbol warns of the risk of injury caused by electricity This symbol warns of the risk of injury caused by explosion and or deflagration...

Page 5: ...rised specialised personnel only Fill the unit with a sufficient quantity of cleaning liquid before switch on Flammable liquids must not be treated by ultrasound directly in the cleaning tank risk of...

Page 6: ...ltrasonic energy is probably the most important mechanical factor in the cleaning process This energy must be transmitted through a liquid medium to the surfaces which are to be cleaned The present El...

Page 7: ...uick degassing of HPLC solvents Auto Degas mode for automatic degassing e g of fresh cleaning liquid detachable mains cable diodes indicating both set and actual values splashwater proof operating pan...

Page 8: ...Stainless steel tank with filling level marking indicates the recommended filling level with litre scale description see section 4 6 Plastic handles for the safe transportation of the unit even when t...

Page 9: ...or transporting the unit Splashwater protection to protect the mains input socket against water ingress Holding support for the rod of the laboratory stand threaded 4 6 Filling level marking in the ta...

Page 10: ...12 h continued operation Key sieve cleaning mode for the cleaning of analysis sieves LED siev clean is lighted during operation of this mode Key degas mode for the optimized degassing of HPLC solvent...

Page 11: ...od Illustration 4 9 1 C Holder set for glass flasks 104 9786 Illustration 4 9 1 Stand rod mounted Screw the threaded end M10 of the stand rod into the support rack on the back of the unit Illustration...

Page 12: ...Vers 08 2011 Elma GmbH Co KG Illustration 4 9 2 1 Sieve holder with laboratory sieve 100 mm Illustration 4 9 2 2 Sieve holder with laboratory sieve 200 mm Illustration 4 9 2 3 Sieve holder with labora...

Page 13: ...er ring that keeps the glass beaker in a certain position and the fitting plastic cover for the beakers Plastic cover with orifice for glass beaker 1049787 The glass beaker Illustration 4 9 4 B is use...

Page 14: ...ace active agent This is necessary to obtain an optimized ultrasonic performance in the bath Standard household washing up liquid can be used Now insert the the filled glass beaker through the orifice...

Page 15: ...on 4 7 A LED remaining time flashes Illustration 4 7 A only in timer operating mode stop ultrasonic operation manually turn turning knob Illustration 4 7 B to the left anticlockwise into position OFF...

Page 16: ...up LED set time lights up LED remaining time flashes switch off sieve cleaning or degas or sample preparation mode press relevant key relevant mode stops operating unit continues operation in standard...

Page 17: ...it from entering humidity The unit inside is splash water proof Keep workplace and casing dry in order to prevent electrical accidents and damages on the unit Allowed ambient temperature during operat...

Page 18: ...ic cleaning bath Use the cleaning chemicals listed in section 8 3 Ultrasonic activity increases the vaporisation of liquids and creates a very fine mist which can catch fire on any ignition source Obs...

Page 19: ...o the stainless steel basket Elma accessory Put laboratory sieves into the sieve holder Elma accessory 6 3 Degassing of liquid Newly mixed cleaning liquid is saturated with air which lessens the clean...

Page 20: ...vices when working close to an ultrasonic unit which is operated without cover Sensitive surfaces can be damaged when exposed to ultrasound over prolonged periods particularly at low cleaning frequenc...

Page 21: ...se In order to avoid unintended continued operation the unit is equipped with an automatic safety switch off The unit switches off completely after 12 h continued operation In case you wish to continu...

Page 22: ...Press the key degas to activate the degas operating mode Sieve cleaning degas and sample preparation modes cannot be operated simultaneously 7 4 Sample preparation mode The Elmasonic S50R can be oper...

Page 23: ...ying and monitoring the results and for inspecting items regularly for potential damage during the treatment lies with the operator 7 6 After the ultrasonic treatment If you have cleaned items in the...

Page 24: ...substances and flammable solvents marked in compliance with the EEC directives by symbols and safety warnings R 1 to R 9 or E F F O or R 10 R 11 or R 12 for flammable substances into the stainless st...

Page 25: ...trasonic bath also apply for the aforementioned chemicals when these are brought into an aqueous particularly distilled water bath through entrainment or from the removed dirt For the ultrasonic treat...

Page 26: ...glass and plastic Removes tenacious contaminations such as rust organic residues inorganic compounds and mineral grease and oil Not suitable for aluminum and light metal alloys Neutral universal and l...

Page 27: ...standard surface disinfectants 9 2 Service life of the transducer tank The transducer tank and particularly the ultrasound transmitting surfaces are wear parts The changes on the surfaces that occur...

Page 28: ...cialised personnel only Risk of electrocution due to live parts inside the unit Pull the mains plug before opening the unit The manufacturer cannot be held responsible for any damage caused by unautho...

Page 29: ...sket internal dimensions Dia x H ca mm Weight ca kg 6 3 5 240 x 30 260 x 350 220 x 70 5 0 Mains voltage versions Vac Ultrasonic frequency kHz Power consumption total W Ultrasonic power effective W Ult...

Page 30: ...ration LED ultrasound dark turning knob for ultrasonic operation in 0 position switch on ultrasonic operation by turning the knob key ultrasound not pressed press key fault of electronics return unit...

Page 31: ...n Phone 49 0 7731 882 0 Fax 49 0 7731 882 266 e mail info elma ultrasonic com Please visit our homepage You will find helpful information and descriptions on our large product range www elma ultrasoni...

Page 32: ...Manufacturer s contact address 32 BA_S50R_EN_Vers 08 2011 Elma GmbH Co KG...

Reviews: