 2. Operation 

 
Fill the unit with liquid before connecting it to the power supply. If you use water  
as contact medium we recommend the use of the suitable ELMA Clean cleaning  
solution to be added to the water. The ELMA Clean chemicals contain tensides  
that reduce the surface tension and are specially designed for the use in an  
ultrasonic bath. Switch on the ultrasonic unit and let the liquid degas for a few  
minutes. Degassed liquids allow better cavitation. Furthermore, special degas- 
improving substances contained in the ELMA Clean chemicals accelerate the  
cavitation process. The use of the cleaning chemicals guarantee a long service  
life of the TRANSSONIC ultrasonic unit.  
The optimum temperature for your specific cleaning task is indicated on the  
label of the used ELMA Clean solution along with the mixing concentration and  
the recommended cleaning time. 
 
If you use pulverised or granulated cleaning media by other suppliers ensure  
that the pulver or granulates dissolve completely. Any residue and particles on  
the tank floor may cause contact corrosion and create pinholes in the material. 
 
The items to be cleaned must be covered completely by the cleaning liquid. We  
recommend to put the items in/on a holder basket to protect the stainless-steel  
tank. Do not put the items directly on the tank floor. These measures  
considerably prolong the service life of the stainless-steel tanks. 
 
If you use aggressive chemicals (e.g. acids, alkalines) we recommend the use  
of plastic tubs (acid-resistant tubs; see Elma catalogue Accessories). 
 
 

3. Analogous Ultrasonic Units 

 
 

off

on

8

ultrasonics

1

5

15

°C

20

30

40

50

60

70

80

heating

off

on

3

7

9

11

13

 
 
 
 
 
 
 
 
 
 
 
 

a) Switch 

On/Off 

 

You switch on the ultrasonic unit by setting the timer or turning the timer  
knob to the infinity position. 
The green lamp (not available on all units) indicates the operation of the  
unit. 

Summary of Contents for Clean 10

Page 1: ...l unit Multi frequency Units Operating Instructions These Operating Instructions are part of the delivered equipment They must be ready for use at any time and remain with the equipment in case of resale These Operating Instructions are not automatically revised For the latest revised issue please contact the manufacturer We reserve the right to carry out modifications concerning the technology or...

Page 2: ...eration Page 5 3 Analogous Ultrasonic Units Page 5 4 Digital Ultrasonic Units Page 6 5 Multi frequency Units Page 8 6 General Page 11 7 Cleaning chemicals Application Page 11 8 Maintenance Page 13 9 Technical Data Regulations Page 14 10 Contact Page 16 2 ...

Page 3: ...ash out The tank of a unit with heating can heat up while operating Do not touch the tank inside when the heating is on Risk of burning Do not reach into the tank during the ultrasonic operation For your information Cell membranes could get damaged by extended exposure to ultrasound Pull the mains plug before emptying the unit by pouring out the liquid Please do not immerse the device in water und...

Page 4: ... high temperatures during ultrasonic operation are e g nitric acid sulphuric acid formic acid hydrofluoric acid even when diluted potassium hydroxide solution leads to stress corrosion cracking in the ultrasonic tank This list is not necessarily conclusive The restrictions on the use of the ultrasonic tank listed above also apply when the chemical compounds cited above are introduced to the tank w...

Page 5: ...ration and the recommended cleaning time If you use pulverised or granulated cleaning media by other suppliers ensure that the pulver or granulates dissolve completely Any residue and particles on the tank floor may cause contact corrosion and create pinholes in the material The items to be cleaned must be covered completely by the cleaning liquid We recommend to put the items in on a holder baske...

Page 6: ...ating is switched on and off by the green button fig 1 Ensure that the filling level in the tank is correct before switching on the heating This prevents overheating of the tank at the spot where the heating is fixed Please note that the liquid will heat up by ultrasonic activity alone without heating This effect is even stronger when a cover is used Heating and ultrasound can be operated separate...

Page 7: ...ndicator 7 The indicator 7 always shows the actual temperature in the cleaning bath Turn the knob clockwise and set the required temperature scale If the required temperature scale is higher than the actual temperature indicator 7 the cleaning liquid will be heated up During the heating up period the right decimal point of the indicator 7 flashes As soon as the required temperature is reached the ...

Page 8: ...nally set period If you want to set the cleaning period back to its original value during operation you do not need to turn the knob 1 again Just press the Start Stop button 8 and keep it pressed for 3 seconds g Special Features All settings can be changed during ultrasonic operation Period Set the new required period by means of knob 1 Ultrasound and temperature indicator stop for 2 seconds Then ...

Page 9: ... between the operation modes sweep standard and degas by means of knob 3 Sweep The frequency varies permanently within a defined range This shifts the minima and maxima of the sound field within the bath It also allows a more even load of the ultrasound transformer The cleaning effect is more homogeneously distributed in the bath than during standard operation Standard The frequency is regulated a...

Page 10: ...ting particles e g oil h Floor scouring optional TI H 25 and larger Particles settling on the tank floor can be washed away by means of the scouring function For this connect both supply 10 and discharge 11 to the external pumping filtering unit i Remote control optional TI H 25 and larger The ultrasound unit can be operated by remote control from a central control unit The remote control is conne...

Page 11: ...cleaning chemical to be used must be suitable for the use in an ultrasonic bath to prevent damage to the transducer tank Do not use flammable products see chapter Safety Warnings Do not use chemicals containing halogenide ions or salt as they may cause pitting corosion in the tank Acids such as hydrochloric acid sulphuric acid or nitric acid destroy the unit in very short time In particular acid c...

Page 12: ...A Clean 65 Neutral universal and laboratory cleaner ELMA Clean 70 Mild alkaline laboratory cleaner ELMA Clean 75 Ammoniacal cleaner with brightening effect for metals cleaner for jewellery Jewellery ELMA Clean 75 Ammoniacal cleaner with brightening effect for metals cleaner for jewellery ELMA Clean 85 Alkali free acid free cleaner for workshop and jewellery manufacture Elma Noble Clean Cleaning an...

Page 13: ...y and remove all residues such as small metal particles or any other kind of dirt before changing the cleaning liquid Small particles in the ultrasonic tank will eventually destroy the stainless steel tank Do not place the items to be cleaned on the tank floor Use a rack or a cleaning basket see paragraph Notes on the Cleaning of Items Do not use any scraping tools A plain and clean metallic surfa...

Page 14: ...5 T 700 H 300x240x150 560 9 5 35 T 95 HL 300x240x150 560 9 5 35 T 780 300x240x200 320 12 75 35 T 780 H 300x240x200 720 12 75 35 T 820 H 327x300x200 1120 18 35 T 890 505x300x200 320 28 35 T 890 H 505x300x200 1120 28 35 TP 1000 H 1000x200x200 1950 40 40 T 1040 H 500x300x300 1950 45 40 T 1060 H 600x500x300 2800 90 40 Tray Dent Tischgerät 320x148x200 320x240x200 320 9 5 15 4 40 LC 20 H 151x137x100 100...

Page 15: ...llowing ambience conditions Electronic voltage 220 240 Vac 50 60Hz or 100 240Vac 50 60Hz except T1060 H TI H55 TI H160 380 400Vac 50 60Hz or 200 208Vac 50 60Hz Max ext Fuse protection 16A Allowed ambient temperature 5 C to 40 C Allowed relative air humidity below 30 C 80 Allowed relative air humidity below 40 C 50 Protect the units from heavy variations in temperature Risk of condensation The unit...

Page 16: ...ss Kolpingstr 1 7 D 78224 Singen Phone 49 0 7731 882 0 Fax 49 0 7731 882 266 Technical Support 49 0 7731 882 280 e mail info elma ultrasonic com homepage www elma ultrasonic com Technical and optical information are subject to change Elma_ch_10 02 16 ...

Reviews: