General specifications
Display:
9999 counts: ACV, DCV, Hz & nS
6000 counts: mV,
A, mA, A, Ohm & Capacitance
Polarity:
Automatic
Update Rate:
Digital Display: 5 per second nominal;
41 Segments Bar-graph: 60 per second max
Low Battery:
Below approx. 7V
Operating Temperature:
0
o
C to 45
o
C
Relative Humidity:
Maximum relative humidity 80% for temperature up to
31
o
C decreasing linearly to 50% relative humidity at
45
o
C
Pollution degree:
2
Storage Temperature:
-20
o
C to 60
o
C, < 80% R.H. (with battery removed)
Altitude:
Operating below 2000m
Temperature Coefficient:
nominal 0.15 x (specified accuracy)/
o
C @(0
o
C ~
18
o
C or 28
o
C ~ 45
o
C), or otherwise specified
Sensing:
BM829s, BM521s & BM525s: AC+DC True RMS
BM827s & 822: AC True RMS
BM821s: Average Sensing
Safety:
Double insulation per IEC/UL/EN61010-1 Ed. 3.0,
IEC/EN61010-2-030 Ed. 1.0, IEC/EN61010-2-033 Ed.
1.0, IEC/UL/EN61010-031 Ed. 1.1 and CAN/CSA-
C22.2 No. 61010-1-12 Ed. 3.0 to Category IV
1000Vac & Vdc.
Transient protection:
12kV (1.2/50
s surge)
Terminals (to COM) Measurement Category:
V / A / mA
A:
Category IV 1000Vac & Vdc
Overload Protections:
A & mA:
0.44A/1000V DC/AC rms, IR 10kA, F fuse
A:
11A/1000V DC/AC rms, IR 20kA, F fuse
V:
1100V DC/AC rms
mV,
& Others:
1000V DC/AC rms
E.M.C. :
Meets EN61326-1:2006 (EN55022, EN61000-3-2,
EN61000-3-3, EN61000-4-2, EN61000-4-3,
EN61000-4-4, , EN61000-4-5, EN61000-4-6,
EN61000-4-8, EN61000-4-11)
In an RF field of 3V/m:
Capacitance function is not specified
Other function ranges:
Total Accuracy = Specified Ac 100 digits
Performance above 3V/m is not specified
Power Supply:
Single 9V battery; NEDA1604G, JIS006P IEC6F22,
NEDA1604A, JIS6AM6 or IEC6LF22
Power Consumption:
5 mA typical
APO Timing:
Idle for 30 minutes
APO Consumption:
50
A typical