v.220630-hlo
14-10-2022 10:16:46
9 Specifications
9.1 Technical specification
Function
Range
Resolution Accuracy
Protection against
overcharge
Length
measurement
range
1000m
0.1m
± (1% r 1 m)
Max. 60V overload
protection
10000m
1m
± (1% r 1 m)
30km
0,01m
± (1.2% r 1 m)
1000ft
0,1ft
± (1% r 3 ft)
10000ft
1ft
± (1% r 1 ft)
100kft
0,01ft
± (1.2% r 1 ft)
Resistance
measurement
range
1999.9 mΩ 0,1mΩ
± (1% r 3
digits
)
Max. 60V overload
protection
19,999 Ω
0,001Ω
± (1% reading
+ 0.5mΩ)
199,99 Ω
0,01Ω
± (1% reading
+ 50mΩ)
1999,9 Ω
0,1Ω
± (1% r 6
digits)
Temperature
-5 to 50°C
0.1 °C
± (2.0% + 1.8 °C)
23 to122°F
0.1 °F
± (2.0% + 1.8 °F)
Accuracy calculated as (% r (number of digits * resolution)) at 0°C to 40°C and <75%HR.
9.2 General specifications
Display
(19999) LCD display
Low battery indication
appears in the display
Over-range indication
The Olympics
are shown in the display
Operating temperature 0 to 40°C (32 to 104°F)
Storage temperature
-20 to 60°C (-4 to 104°F)
Operation humidity
Max 80% up to 31 °C (87 °F) decreasing linearly to 50% at 40 °C (104 °F)
Storage humidity
< 80%
Drop Protection
1m (3.3ft)
Battery life
Capacity ~ 900mAh
Auto Power Off
After approx. 15 min.
Dimension
212 X 100 X 67mm
Weight
600g
Summary of Contents for 6501