16. Residual risks
The residual risks associated with the machine are minimized by the manufacturing standards such as the safety voltage (12Vdc) in use on the machine
and the correct operation of the grounding system which guarantee the safe use of the Washer 120. Nevertheless, the following situations can occur
due to incorrect use of the product:
Residual risks are reduced if the instructions and the guidelines contained in this manual are followed strictly.
N.
1
2
Residual Risks
Spilling of liquids on the floor that can render the treading surface slippery due to improper filling of the wash basins and of the
devices, caused by arbitrary acts of the technician.
Risk of electrocution due to erroneous connection of the power cord connected to the 230 Vac voltage socket
17. Maintenance
PROBLEMS, DEFECTS
The following is a list of the possible defects that can appear, their causes and the proposed countermeasures for resolving them:
Solution
Problem
Cause
Check the position of the main switch on the front panel
Check the presence of electric current
The system is in battery mode, it will automatically adjust when elec-
tricity is restored.
Contact the technical assistance center
If the attempt proves negative - Contact the technical assistance center
The Dogma 100/ 90 does not
perform any function
The indication light (LED) next to
the main switch is flashing
The SIR does not work
The electronic mixer does not
work
The main switch is in the ‘off’ position-
the indication light (LED) is off
Electricity is not flowing
Electricity is not flowing
Failure of the control panel
Follow the checklist found in the adden-
dum section “ELECTRONIC MIXER”
The technology used in the Dogma 100/Dogma 90 does not permit the intervention of unqualified individuals, without adequate tools and parts, in
order to guarantee the correct restoration of the product.
WE RECOMMEND THAT MAINTENANCE ALWAYS BE CARRIED OUT BY AN AUTHORIZED TECHNICAL ASSISTANCE CENTER
IMPORTANT
In case of replacement, use batteries NIMh size AAA of 800 mAh
dimensions mm10x44
To maintain its beautiful appearance for a long time to come, we suggest you care as it follows: Bright chrome, velvet and colour coated surfaces
are sensitive to cleaning agents containing acids or abrasives as well as abrasive sponges.
Slight colour variations can occur with colour coated mixers as a result of unavoidable process variations
MAINTENANCE
Dirt and surface calcination are best removed with soapy water, fellowed by rinsing with plain water and drying. Do not use disinfectants or cleaning
agents containing alcohol.
Careless treatment of faucets invalidates Elleci S.p.a. guarantee provisions.
Care and maintenance instructions
COLOUR COATED SURFACES REQUIRE EXTRA CARE URING INSTALLATION AND USE.