The Front Legs must
be screwed into the
subfloor to assure
stability

www.ellasbubbles.com 

07/2022

Door and Frame Adjustments

Warning:

 Make sure all legs

are leveled and that they
touch/sit on the floor evenly.

Back Nut

Adjustable Height Leg

A closer view of the
leg is shown below

Page. 8

Note: 

Graphic above does

NOT reflect the actual frame.

Your walk in bathtub has been tested and leveled properly before leaving our facility. Our
Microbubble Pet Spa have been set on a perfectly level surface to ensure no leaks and proper door
closing. It is up to your installer to test and make any adjustments necessary to ensure that all leveling
legs support the tub frame and that the door is aligned correctly to prevent any leaks. The door must
close smoothly to create a water tight seal. If the tub is not perfectly leveled, it may cause frame and
shell warping which can cause changes in door alignment resulting in water leakage and void the
warranty. 

Extending or shortening the legs will help correct any alignment issues to close the gap between the
door and the frame. Please call 

1-800-480-6850

 immediately if any issues arise or if you have any

concerns. 

Summary of Contents for ELLA MICROBUBBLE THERAPY PET SPA

Page 1: ...Customer Support 800 480 6850 Email info ellasbubbles com ELLA MICROBUBBLE THERAPY PET SPA OWNERS MANUAL ellasbubbles com...

Page 2: ...ellasbubbles com 07 2022 Unpacking and Inspecting the Pet Spa Upon receiving your Pet Spa please inspect the crate and carton for any damages If damages found please take few pictures of damages with...

Page 3: ...o so will cause loosening over time resulting in it coming apart and falling down the drain www ellasbubbles com Pet Spa Drain Installation Warning Drain open all the way Drain closed completely WARNI...

Page 4: ...injury do not permit children or persons with disabilities to use this product unless they are supervised by an able bodied adult at all times Never drop or insert any objects into any openings CAUTI...

Page 5: ...ne to plug in a single connection Water Test It is important to test that the Microbubble Therapy System is functioning properly before final in wall installation to avoid unnecessary repairs or remov...

Page 6: ...Cable Operated Lever 2 PVC Coupling www ellasbubbles com 07 2022 2 PVC drain connected via PVC glue to a 2 drain pipe 2 PVC Drain Overflow PEX Tubing Overflow PEX Tubing Page 7...

Page 7: ...tly level surface to ensure no leaks and proper door closing It is up to your installer to test and make any adjustments necessary to ensure that all leveling legs support the tub frame and that the d...

Page 8: ...od of time throughout shipping and the bathtub has been stored in various temperatures It is possible for the silicone seal to stick to the frame when stored for extended periods of time When the bath...

Page 9: ...ing or thermal shock There are circumstances where inlet temperature and pressure are inconsistent and pose potential danger to a bather Responding to these variations in temperature and pressure is t...

Page 10: ...ses the hot water inlet port gets blocked by the seat assembly That is adjusted by the expansion of the thermostat In both cases outlet water temperature is fixed at a set point How Does A Thermostati...

Page 11: ...movable Platform For Larger or Smaller Sized Dogs Microbubble Hand Shower with Ozone Sterilization Twenty 20 Adjustable Sidewall Jets Ten 10 Jets Per Side Aluminum Door with Stainless Steel Hinges Han...

Page 12: ...ed for small to medium sized dogs Once your pet is in the tub close the door and hook them up to the dog chain s for added security and safety 2 dog hooks available Thermostatic Control Valve TCV 2 Tu...

Page 13: ...rn the diverter clockwise See Image 2 To turn the hand shower off turn the second lever to the left See Image 1 Image 1 Image 2 Note The side wall jets can be used on their own with the hand shower an...

Page 14: ...omer The removal and cleaning of TCV should only be performed by a licensed and insured contractor or plumber following online instructions Non Ella brand faucets are not covered under this warranty P...

Page 15: ...dicated GFCI protected circuit ____ Frame of the tub has been properly grounded ____Door Seal has been cleaned with rubbing alcohol to remove any dust or debris left over from construction ____Tempera...

Page 16: ...______________ ________________________________________________________________________ Telephone Email _________________________________ ______________________________________________________________...