Connections 

The use of AWG 16 or Ø 1mm cables is recommended. 

1. Connect the Phase Output and Neutral Output terminals to the load 
2. Connect the power relay to the Phase Input and Neutral Input of the 230Vac 
power supply. A fast flashing of the LED indicates that the device is now ready for 
the learning phase to the system. 
3. It is possible to connect an external switch, "parallel" to the power relay, as 
shown on the side, to switch the connected load on / off. 

Joining the Network 

Please follow the steps below to join the Power Relay Switch into the network. 

  Connect the Power Relay Switch to power cable. 
  Set the control unit to learning mode (see the instruction manual of the control unit for details). 
  Press and hold the Function button for 10 seconds, then release it to join the network. If the device successfully joins 

the network, the LED Indicator will flash twice to confirm. 

Removing Device from Network (Factory Reset) 

Factory Reset function can clear the device of its stored setting and information and prompt it to search for new network.  

1.  Press and hold the function button for 10 seconds, then release the button to reset the Relay Switch.

 

2.  The device will perform its factory reset.

 

3.  Fully follow the previous instructions to join again the device

 

IMPORTANT NOTE

: DO NOT

 use the Power Relay Switch as router for your security sensor or alarm control devices. 

 

SIMPLIFIED EU DECLARATION OF CONFORMITY 

Hereby, URMET S.p.A. declares that the radio equipment type: POWER RELAY SWITCH RM600

 

is in compliance with Directive 

2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: www.elkron.com. 

CLICK  ON  THE  FOLLOWING  LINK  OF  THE  ELKRON  SITE  TO  ACCESS  THE  PRODUCT 
TECHNICAL SHEET AND DOWNLOAD THE COMPLETE MANUAL

 

 

 

DIRECTIVE 2012/19/EU OF THE EUROPEAN PARLIAMENT  AND OF THE COUNCIL of 4 July 2012 on waste electrical and electronic 
equipment (WEEE). 

The symbol of the crossed-out wheeled bin on the product or on its packaging indicates that this product must not be disposed of 

with your other household waste. 

Instead, it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the 

recycling of waste electrical and electronic equipment. The separate collection and recycling of your waste equipment at the time of 

disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the 

environment. For more information about where you can drop off your waste equipment for recycling, please contact your local city office, your 

household waste disposal service or the shop where you purchased the product.

 

 

ELKRON 

 

Tel. +39 011.3986711 - Fax +39 011.3986703 

www.elkron.com

 – mail to: [email protected]

  

ELKRON 

is a trademark of 

 

URMET S.p.A. 

Via Bologna, 188/C - 10154 Torino (TO) – Italy 

www.urmet.com

     

 

LED indicator

 

Function Button

 

External Switch Terminal 2

 

External Switch Terminal 1

 

AC Line Power Load Output

 

AC Line Power Input

AC Neutral Power Input

AC Neutral Power Load Output