MEDEA Programming Manual
133
9 -
Updating firmware and software of MEDEA control
panel and devices over the bus
It is possible to update the firmware (FW) and software (SW) of the MEDEA control panel and connected
BUS devices using various procedures:
•
Over LAN with local or remote connection.
•
Directly from a PC to MEDEA control panel over USB cable.
•
Directly from a PC to MEDEA control panel over Ethernet cable.
The procedures require access to the programming web pages of the control panel and are described in
the paragraphs (see
paragraph 3.1 Accessing the control panel
) and then in the General Parameters
submenu (see
paragraphs 1.1 4.1.3 Control Unit Upgrade from cloud
Errore. L'origine riferimento non
è stata trovata.
and
4.1.4 Control Unit Update from File
9.1
Update file name
Update file names use the following conventions:
Update type
Description
File name
Application
Control panel software, which manages the
entire system.
*_APPLICATION_*.BIN
Control panel
Firmware of the control panel, which manages
the inputs and outputs of the control panel,
expansion
modules,
keypads,
readers,
wireless receivers and supervised power
supply units
*_CARRIER_BOARD_*.BIN
Expansion modules
*_EXP_MODULE_*.BIN
LCD keypads
*_KEYPAD_*.BIN
Capacitive keypads
*_CAP_KPAD_*.BIN
Readers
*_TRANSPONDER_*.BIN
Receivers
*_RADIO_RX_*.BIN
Power supply units
*_POWER_SUPPLY_*.BIN
Table 16 - FW and SW update file names
NOTES
: File names can be written in upper and/or lower case.
The * character represents a character string that can vary from file to file, e.g. to indicate the
firmware version, e.g. BL_EXP_MODULE_v101b05.BIN is the upgrade file for expansion module
version 1.1b05.
This installation manual refers to version SW 1.5_100 of MEDEA control units and version FW 1.1_25 of
BUS line peripheral devices