HP201 / HP202L / HP202LG
2/8
• High mechanical resistance polycarbonate external box.
• Controls managed by microprocessor.
• BL and TC lock inputs with positive or negative reference.
• Poss
ibility of programming sounder when lock signal is permanently down.
• Sounder counter: up to 5 over 24h or per activation sequence (TC transition).
• Alarm log for units with TC output (flasher blinking).
•
System status report function: TC signal absence from control panel will cause continuous flash
blinking.
• Battery polarity inversion protection and power via control unit.
• Anti-opening and anti-removal protection.
• Initial lock f
unction: the flasher will blink and the siren will not sound at first power-up ; connect lock signal
(BL) and TC unit to set up siren for operation.
• Siren stops when the lock signal is down for longer than the programmed time. A new alarm cycle
will be generated if the lock signal goes down again (see "Siren programming").
• Acoustic pressure: 104 dB(A) - HP201 - HP202L models
102 dB(A) - HP202LG model
• Internal low battery saver function stops the flasher and privileges the siren.
1.00 General description
HP 201
NO
OPTIONAL
HP 202 L
YES
OPTIONAL
HP 202 LG
YES
YES
MODEL
FILAMENT
FLASHER
I N T E R N A L
PROTECTIVE
CAGE
(HP7410111)
CONTENTS
1.00
GENERAL DESCRIPTION ......................................................... 2
2.00
INSTALLATION........................................................................... 3
3.00
TERMINAL BOARD .................................................................... 4
4.00
SIREN PROGRAMMING ............................................................ 5
5.00
ALARM MANAGEMENT ............................................................. 5
6.00
TECHNICAL SPECIFICATIONS ................................................ 6
7.00
EXAMPLES OF CONNECTION ................................................... 7