ADDRESSING 

The  address  (1-128)  is  software  set  and  stored 
in a non-volatile memory.  
The  detector  can  be  addressed,  in  manual  or 
automatic mode from the Control Panel. 
For  further  details  see  the  Control  Panel’s 
programming manual.

 

 

MOUNTING

 

Lean  the  detector  head  on  the  base;  while 
pressing,  turn  it  clockwise  until  it  enters  in  the 
seat of the base as illustrated in the figure. 
 

 

CONNECTIONS 

The  detector  head  must  be  used  in  conjunction 
with SD500 or SD500R standard base.  
For example of connections, please refer to the 
standard base’s SD500 - SD500R manual. 
In  order  for  the  device  to  work  properly,  it  is 
recommended  to  seal  the  openings  in  the  base 
of the detector used for the cables to go through. 

 

The 

FDO500 

is  only  to  be  used  with  ELKRON 

FAP series Control Panels. 
 

TESTING 

(trained personnel)

 

Before testing, notify to competent authority that 
the  system  is  temporarily  out  of  service  due  to 
maintenance operations. 

 

The  detectors  can  be  tested  in  the  following 
way: 

A - Functional test

 

It  is  a  simulation  of  smoke  presence  obtained 
from  the  insertion  of  rigid  white  wire  (

ø

  <1mm)  

in the test hole until the alarm occurs. 
 
 
 
 

B - Smoke entry test 

Use a manufacturer-approved test equipment. 

  Use an aerosol canister locked into the proper 

test dispenser. 

 Follow  the  test  instruction  attached  to  the 

canister. 

 

C - Temperature test 

It is a simulation of high temperature. 
Use  a  hot  air  flow  on  the  thermal  element  of 
detector until  the alarm occurs. 

 

At  the  end  of  testing  operations,  restore  the 
system to normal operation and notify the status 
to the competent Authorities. 
 

TECHNICAL SPECIFICATIONS 

 

Light source 

GaAlAs infrared emitting 
diode 

Operating voltage 

20 Vdc (-15%, +10%) 
modulated 

Average power 
consumption 
(Normal condition) 

250 

A @ 20Vdc 

Average power 
consumption 
(Alarm condition) 

2 mA @ 20Vdc 

Bi-Colour LED 

Red steady: 
alarm condition 
Red blinking slow (2s): 
alarm condition with SLC 
operating voltage < 17V 
Green blinking slow (2s): 
normal condition 
Green blinking fast : 
duplicate address 

Operating temperature 

-10 

 55°C ± 2°C 

(14 

 131°F) 

Relative humidity 

93 % ± 2%  
non-condensing 

Storage/shipping 
temperature 

-30 

 70 °C 

(-22 

 158°F) 

Dimensions: 

Diameter 

Height 

 
90 mm (3.54 inc) 
31 mm (1.22 inc) 

Weight 

70 g 

Enclosure material 

ABS V0 

In compliance with  EN54-7:2000/A2:2006 
                           EN54-17:2005/AC:2007 
Optical Smoke detector mod. FDO500                
Urmet S.p.A. 1293-CPD-0340 
DoP n. 1293-CPR-0340                                                  

 

Further information are available to the manufacturer.             

 

08 

 

1293 

Summary of Contents for FDO500

Page 1: ...visualizzare l indirizzo del rivelatore tramite una funzione attivata dalla centrale Per ulteriori informazioni fare riferimento al manuale programmazione delle centrali ELKRON serie FAP54 MANUTENZION...

Page 2: ...inserendo un filo rigido bianco nel foro di test fino al verificarsi dell allarme B Test Fumo Simulato Usare prodotti approvati dal costruttore Seguire le istruzioni riportate sul prodotto Attendere c...

Page 3: ...LED green red in operating mode indicates the detector condition while in service mode it can be used to show the detector s address by a special function activated from the Control Panel For further...

Page 4: ...il the alarm occurs B Smoke entry test Use a manufacturer approved test equipment Use an aerosol canister locked into the proper test dispenser Follow the test instruction attached to the canister C T...

Page 5: ...esde la central Para m s informaci n ver al manual de programaci n de la central ELKRON serie FAP MANTENIMIENTO personal autorizado La central autom ticamente indica que el sensor necesita mantenimien...

Page 6: ...r un producto aprobado por el fabricante Seguir las instrucciones indicadas sobre el mismo producto Observar que la sea se alizada la condici n de alarma C Test Funcional de Temperatura El uso de un c...

Page 7: ...on its packaging indicates that this product must not be disposed of with your other household waste Instead it is your responsibility to dispose of your waste equipment by handing it over to a desig...

Page 8: ...02 334491 Fax 39 02 33449213 www elkron com mail to info elkron it ELKRON un marchio commerciale di URMET S p A ELKRON is a trademark of URMET S p A ELKRON es una marca registrada de URMET S p A Via B...

Reviews: