RFSA-62B
Wireless switch unit
EN
02-49/2015 Rev.1
5/5
Technical parameters /
S
upp
l
y
vo
l
ta
g
e
:
A
pparent
input
:
Dissipated
po
w
er
:
S
upp
l
y
vo
l
ta
g
e
to
l
erance
:
O
utput
N
umber
o
f
contacts
:
R
ated
current
:
Sw
itchin
g
po
w
er
:
P
eak
current
:
Sw
itchin
g
vo
l
ta
g
e
:
M
a
x
.
DC
s
w
itchin
g
po
w
er
:
M
echanica
l
service
l
i
f
e
:
El
ectrica
l
service
l
i
f
e
(A
C1
):
Contro
l
RF,
by
command
f
rom
transmitter
:
M
anua
l
contro
l:
R
an
g
e
in
f
ree
space
:
O
ther
data
O
peratin
g
temperature
:
O
peratin
g
position
:
M
ountin
g:
P
rotection
:
O
vervo
l
ta
g
e
cate
g
ory
:
Contamination
de
g
ree
:
T
ermina
l
s
(
C
Y w
ire
,
cross-section
):
L
en
g
th
o
f
termina
l
s
:
Dimensions
:
W
ei
g
ht
:
R
e
l
ated
standards
:
Warning
Instruction manual is designated for mounting and also for user of the device. It is always a part of its packing.
Installation and connection can be carried out only by a person with adequate professional qualifi cation upon
understanding this instruction manual and functions of the device, and while observing all valid regulations.
Trouble-free function of the device also depends on transportation, storing and handling. In case you notice any
sign of damage, deformation, malfunction or missing part, do not install this device and return it to its seller. It
is necessary to treat this product and its parts as electronic waste after its lifetime is terminated. Before starting
installation, make sure that all wires, connected parts or terminals are de-energized. While mounting and servicing
observe safety regulations, norms, directives and professional, and export regulations for working with electrical
devices. Do not touch parts of the device that are energized – life threat. Due to transmissivity of RF signal, observe
correct location of RF components in a building where the installation is taking place. RF Control is designated only
for mounting in interiors. Devices are not designated for installation into exteriors and humid spaces. The must not
be installed into metal switchboards and into plastic switchboards with metal door – transmissivity of RF signal is
then impossible. RF Control is not recommended for pulleys etc. – radiofrequency signal can be shielded by an
obstruction, interfered, battery of the transceiver can get fl at etc. and thus disable remote control.
PROG
> 5s
1 x
PROG
> 8s
1 x
Delete actuator /
Deleting one position of the transmitter /
By pressing the programming button on the actuator for
5 seconds, deletion of one transmitter activates. The LED
fl ashes in an interval of 1s.
Pressing the required button on the transmitter deletes it from
the actuator's memory.
The LED goes out and the actuator returns to operating mode.
Deleting the entire memory /
By pressing the programming button on the actuator for
8 seconds, deletion occurs of the actuator's entire memory. The
LED fl ashes three times and goes out, then again fl ashes three
times and goes out.
The actuator goes into the programming mode, the LED fl ashes
in 0.5s intervals (max. 4 min.).
You can return to the operating mode by pressing the Prog
button for less than 1s.
Attention:
The minimum distance between the controller (system unit) and the actuator must not be less than one
centimeter.
Between the individual commands must be an interval of at least 1s.
Funkgesteuerte Schalteinheit
DE
ELKO EP, s.r.o. | Palackého 493 | 769 01 Holešov, Všetuly | Czech Republic | e-mail: [email protected] | Support: +420 778 427 366
ELKO EP Germany GmbH | Minoritenstr. 7 | 50667 Köln | Deutschland | E-mail: [email protected] | Tel: +49 (0) 221 222 837 80
www.elkoep.com / www.elkoep.de
2
3
0
V
A
C
/
50
-
60
H
z
120
V
A
C
/
60
H
z
12-2
4
V
A
C
/
DC
50-60
H
z
7
V
A /
cos
φ =
0.1
7
V
A /
cos
φ =
0.1
-
0.
7 W
0.
7 W
0.
7 W
+
10
%
;
-15
%
2
x
s
w
itchin
g / S
cha
l
tkontakt
(AgS
n
O
2
)
8
A / A
C1
2000
V
A / A
C1
10
A / < 3
s
250
V
A
C1
500
m
W
1
x
10
7
1
x
10
5
868
MH
z
,
915
MH
z
,
916
MH
z
button
/ T
aste
PROG (ON/OFF)
up
to
/
bis
zu
100
m
-15
...
+
50
°
C
any
/
be
l
iebi
g
f
ree
at
l
ead-in
w
ires
/ F
rei
an
den
A
nsch
l
ussdr
ä
hten
IP3
0
III
.
2
2
x
0.
7
5
mm
2
,
2
x
2.5
mm
2
90
mm
4
9
x 4
9
x
21
mm
4
6
g
EN
60669
, EN 3
00220
, EN 3
01
4
89
R&TTE
Directive
, O
rder.
N
o
4
26
/
2000
Co
ll
.
(
Directive
1999
/E
C
) /
EN
60669
, EN 3
00220
, EN 3
01
4
89
R
icht
l
inie
RTTE, RG N
r.
4
26
/
2000
Sgl
.
(R
icht
l
inie
1999
/EG)
Technische Parameter
S
pannun
g
sversor
g
un
g:
S
chein
l
eistun
g E
in
g
an
g:
Ver
l
ust
l
eistun
g:
T
o
l
eranz
der
S
pannun
g
sversor
g
un
g:
A
us
g
an
g
A
nzah
l
der
Kontakte
:
M
essstrom
:
S
cha
l
t
l
eistun
g:
S
pitzenstrom
:
S
cha
l
tspannun
g:
M
a
x
.
DC
S
cha
l
t
l
eistun
g:
M
echanische
L
ebensdauer
:
El
ectrische
L
ebensdauer
(A
C1
):
S
teuerun
g
RF S
i
g
na
l
e
von
den
S
endern
:
M
anue
ll
e
S
teuerun
g:
R
eich
w
eite
im
F
reien
:
A
ndere
Daten
A
rbeitstemperatur
:
A
rbeitsposition
:
I
nsta
ll
ation
:
S
chutzk
l
asse
:
Ü
berspannun
g
skate
g
orie
:
Verschmutzun
g
s
g
rad
:
A
nsch
lü
sse
(
C
Y
Draht
, Q
uerschnitt
):
Lä
n
g
e
des
T
ermina
l
s
:
A
bmessun
g
en
:
G
e
w
icht
:
S
tandards
:
Warnung
Die Betriebsanleitung dient der Montage, sowie dem Benutzer des Geräts. Sie ist immer im Lieferumfang enthalten.
Die Montage und der Anschluss darf nur durch eine Person mit einer angemessenen Berufsqualifi kation, nach dieser
Bedienungsanleitung und Funktionen des Gerätes und unter Beachtung aller gültigen Vorschriften ausgeführt
werden. Die störungsfreie Funktion des Gerätes hängt auch von Transport, Lagerung und Handhabung ab. Falls Sie
irgendwelche Anzeichen von Beschädigung, Verformung, Fehlfunktionen oder Fehlteilen feststellen, ie das Gerät
nicht und wenden sich an den Verkäufer. Es ist notwendig, dieses Produkt und Teile davon als Elektronikschrott
zu behandeln, nachdem seine Lebensdauer beendet ist. Vor Beginn der Montage ist sicherzustellen, dass alle
Leitungen, miteinander verbundenen Teilen oder Anschlüsse spannungsfrei sind. Während der Montage und
der Wartung sind die Sicherheitsvorschriften, Normen, Richtlinien für die Arbeit mit elektrischen Geräten zu
beachten. Berühren Sie keine Teile des Gerätes, die mit Energie versorgt werden - Lebensgefahr. Aufgrund der
Sendeleistung des RFSignals, beachten Sie den geeigneten Montageort der RF-Komponenten in einem Gebäude,
in dem die Installation stattfi ndet. RF Control ist nur für die Montage im Innenbereich geeignet. Geräte sind
nicht für die Montage in Außenbereichen und Feuchträumen geeignet. RF Control Komponenten dürfen nicht
in Metallschalttafeln und in Kunststoff - Schalttafeln mit Metalltür installiert werden - Die Durchlässigkeit des
RF-Signals ist dann nicht gegeben. RF Control ist nicht für Aufzüge geeignet - das RF Signal kann gestört und
abgeschirmt werden, die Batterie des Emfängers verliert schnell die Leistung etc. - dieses verhindert die Steuerung
durch eine Steuerungseinheit.
Aktor löschen
Löschen von einer Position des Aktors
Durch Drücken der Programmiertaste auf dem Aktor für
5 Sekunden, wird der Löschmodus aktiviert. Die LED blinkt im
Abstand von 1s.
Drücken Sie die gewünschte Taste des Senders löscht sie aus
dem Speicher des Aktors.
Die LED erlischt, der Aktor ist nun wieder in dem Betriebsmodus.
Den gesamten Speicher löschen
Durch Drücken der Programmiertaste auf dem Aktor für
8
Sekunden, erfolgt die Aktivierung der Löschung des
gesamten Speichers. Die LED blinkt dreimal und erlischt dann
wieder dreimal und erlischt.
Der Aktor geht in den Programmiermodus, und die LED blinkt
in 0.5s Intervallen (max. 4 min.).
Sie können in den Betriebsmodus durch Drücken der Prog-
Taste für weniger als 1s zurückgelangen.
Achtung:
Die Entfernung zwischen Sender und Empfänger sollte nicht weniger als 1 cm betragen.
Zwischen aufeinanderfolgenden Befehlseingaben sollte mindesten 1s Abstand liegen.