background image

2 / 2

DIM-2

T1

t1

t3

t2

T2

t1

t3

t2

Warning

Technical parameters

Function

 -  brightness

T1, T2 - controlling input
t1 - dim-up time

Controlled via input T1 (button)
Dim-up delay-down is started by a button. 
Cycle extension - by re-pressing button 
(during the cycle).

t2 - time delay
t3 - dim-down time

Controlled via input T2 (switch)
The switch starts the cycle and it stops on 
max.set brightness. After the switch is off , 
the cycle will continue until completed.

Device is constructed for connection in 1-phase main AC and must be installed according to  
norms valid in the state of application. Connection according to the details in this direction. In-
stallation, connection, setting and servicing should be installed by qualifi ed electrician staff  only, 
who has learnt these instruction and functions of the device. This device contains protection 
against overvoltage peaks and disturbancies in supply. For correct function of the protection of 
this device there must be suitable protections of higher degree (A, B, C) installed in front of them. 
According to standards elimination of disturbancies must be  ensured. Before installation the 
main switch must be in position “OFF” and the device should be de-energized. Don´t install the 
device to sources of excessive electro-magnetic interference. By correct installation ensure ideal 
air circulation so  in case of permanent operation and higher ambient temperature the maximal 
operating temperature of the device is not exceeded. For installation and setting use screw-driv-
er cca 2 mm. The device is fully-electronic - installation should be carried out according to this 
fact. Non-problematic function depends also on the way of transportation, storing and handling. 
In case of any signs of destruction, deformation, non-function or missing part, don´t install and 
claim at your seller. After the product exceeds lifetime, it should be removed and placed in pro-
tected dump. Important advice and warning: Dimmer is designated for managing brightness of 
el. bulbs, in case of low-voltage halogen lights with separating ferromagnetic transformer. It is 
not suitable for connecting electronic transformers. 
Important instructions and cautions - dimmer is not designated for controlling of motors or oth-
er inductive loads. HDO warning signals and other similar signals spreaded by main, can cause 
interruption of dimmer. Interruption is active only during transmitting of these signals.

Supply terminals:

Supply voltage:

Consumption:

Supply voltage tolerance:

Supply indication:

Time setting:

Time deviation:

Repeat accuracy:

Temperature coeffi

  cient:

Reset time:

Controlling T1

Control terminals:

Control voltage:

Power on control input:

Impulse length:

Glow-lamps:

Max. amount of glow lamps

connected to controlling input:

Controlling T2

Control terminals:

Control voltage:

Power on control input:

Impulse length:

Output

Rated current:

Resistance load:

Inductive load:

Other information

Operating temperature:

Storage temperature:

Operating position:

Mounting:

Protection degree:

Overvoltage cathegory:

Pollution degree:

Max. cable size (mm

2

):

Dimensions:

Weight:

Standards:

A1-A2

AC 230 V / 50 Hz

max. 5 VA

-15%; +10%

green LED

potentiometers

10 % - mechanical setting

5 % - set value stability

0.01 % /°C, at = 20°C

max. 80 ms

T1-A1

AC 230 V

max. 1.5  VA

min. 100 ms / max. unlimited 

yes 

max. amount 50 pcs

(measured with glow lamp 0.68 mA / 230 V AC) 

T2-A1

AC 230 V

0.1 VA

min. 100 ms / max. unlimited

2 A

10 - 500 VA

10 - 250 VA

-20 °C to +55 °C (-4 °F to 131 °F)

-30 °C to +70 °C (-22 °F to 158 °F)

any

DIN rail EN 60715

IP40 from front panel / IP10 terminals

III.

2

solid wire max. 2x 2.5 or 1x 4 / 

with sleeve max. 1x 2.5 or 2x 1.5 (AWG 12)

90 x 17.6 x 64 mm (3.5˝ x 0.7˝ x 2.5˝)

65 g (2.3 oz.)

EN 60669-2-1; EN 61010-1