background image

Page 6

98982C  (Rev. K - 06/16)

B

C

A

SIMPLY PUSH IN

TUBE TO ATTACH

TUBE IS SECURED

IN POSITION

PUSH IN COLLET

TO RELEASE TUBE

OPERATION OF QUICK CONNECT FITTINGS

PUSHING TUBE IN BEFORE

PULLING IT OUT HELPS TO

RELEASE TUBE

OPERATION OF QUICK CONNECT FITTINGS

SIMPLY PUSH IN

TUBE TO ATTACH

TUBE IS SECURED 

IN POSITION

PUSH IN COLLET

TO RELEASE TUBE

PUSHING TUBE IN BEFORE 

PULLING IT OUT HELPS TO 

RELEASE TUBE

A

B

C

Fig. 4

 

Note:  Screw the locknut hand tight to seal

Fig. 5

MOUNTING SCREW 

DO NOT REMOVE

MOUNTING SCREWS

TOP COVER

MOUNTING SCREWS

DO NOT REMOVE

Fig. 3

MOUNTING BRACKET

FOR FASTENING UNIT

TO WALL

WATER COOLER

BOTTLE FILLER

BOTTLE  FILLER  INSTALLATION

1)

Remove wall mounting plate(s)

 from Cooler(s). Install Wall Mounting Plate(s) as per rough-in diagrams on sheet 2 or 3 of this instruction.

NOTE:

 Mounting plate(s) 

MUST

 be supported securely. Add fixture support carrier if wall will not provide adequate support.

2)

For Single Model Installations:

 Install water cooler onto wall bracket and secure to wall. Connect drain and water inlet to cooler as required (See rough- 

      in on page 2). 

DO NOT

 connect power to cooler at this time or turn water supply on.

2a) 

 For Two Level Model Installations:

 Install lower water cooler only at this time onto bracket as per rough-in diagram on sheet 3.

3)

Remove VRC Bottle Filler

 from carton.

 

Remove 3/8” to 1/4” reducing union from end of waterline, (do not throw away it will be needed later). Lay Bottle Filler 

on water cooler basin and cut insulation from tube even with bottom of unit, remove this insulation from the 3/8” tube, but do not discard.  Feed the power 

cord, and waterline through the hole on top of water cooler. Feed the Reset Button wire from circuit board down through the hole in the basin.

NOTE:

 To prevent scratching the basin place a towel or soft cloth over the entire basin when working above it.

4)

With the power cord,

 waterline and reset button wires through the hole on top of water cooler place Bottle Filler on to mounting bracket on basin.

(See Fig. 3). Make sure bottle filler is installed properly on the basin gasket

5)

Once Bottle Filler

 is installed on basin mounting bracket, tighten the two screws (supplied) one on each side of the bottle fille .  Install Top Cover on Bottle 

Filler (See FIG. 3) with two mounting screws (supplied) . Caution do not over tighten screws.

6)

For Two Level Model Installations:

 Secure non-refrigerated unit to wall, connect drains and water inlet. Connect black reset button wires from 

non-refrigerated unit to the black wires on the refrigerated unit (see step 4).

6a) 

For Reversed Two Level Model Installations:

 Secure refrigerated unit to wall, connect drains and water inlet. Connect the black reset button wires from the

      non-refrigerated unit to the bottle filler unit above

7)

For Single Model Installations:

 Install remaining tube insulation to the water line from bottle fille , connect Bottle Filler waterline inside of the water cooler

by connecting the 3/8” water line with the 3/8” to 1/4” union and short piece of poly tube that was previously installed to the tee at the evaporator outlet. 

7a) 

For Two Level Model Installations: 

Install the 1/4” poly tubing and insulation from the outlet of the filter to the union on top of the evaporato . Install the 

      1/4” poly tubing and insulation from the regulator in the non-refrigerated cooler to one of the tees at the evaporator outlet. Install remaining tube 

      insulation to the water line from bottle fille , connect Bottle Filler waterline inside of the water cooler by connecting the 3/8” water line with the 3/8” to 1/4”   

      union and short piece of poly tube that was previously installed to the tee at the evaporator on the refrigerated cooler. 

8)

Install filter cartridge,

 remove filter from carton, remove protective cap, attach filter to filter head by firmly inserting into head and rotating filter clock

NOTE:

 If existing plumbing rough-in locations (Drain, Water In, Electric Supply) do not allow the filter to be mounted inside the cooler cabinet

the filter can be installed horizontally below the unit.  A retrofit kit is available to mount the filter beneath the cool .

9)

Turn water supply on

 and inspect for leaks. Fix all leaks before continuing.

10)

Once unit has been inspected 

for leaks and any leaks found corrected, plug Bottle Filler and LVRC unit into wall. Be sure to reinstall fuse to the circuit 

or switch the circuit breaker back to the “ON” position.

11)

Once power is applied to Bottle Filler

, the GREEN LED light should illuminate showing good filter status along with the LCD Bottle Counte .

12)

Verify proper dispensing 

by depressing the button at the top of the Bottle Filler and verify water dispenses.  Note: the first initial dispense

might have air in line which may cause a sputter.  This will be eliminated once all air is purged from the line.

14)

Once unit tests out,

 install Lower Panel back on LVRC water cooler(s).  Unit is now ready for use.

NOTE: TRIM PLATES MUST 

BEINSTALLED ON THE 

INSIDE OF THE BOTTLE 

FILLER SIDE PANEL SLOTS

Buy at

| 855-558-9600 | BottleFillingStations.com

Summary of Contents for VRC8WS

Page 1: ...LATION CARE USE MANUAL IMPORTANT THIS IS AN INDOOR OUTDOOR APPLICATION ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON Model VRC8WS Model VRCTL8WS Model VRCTLR8WS Buy at 855 558 9600 Bottl...

Page 2: ...COMMON PROCEDURE THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE BUILDING THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN CREATING AN ELECTROLYSIS WHICH CAUSES A METALLI...

Page 3: ...4 X 1 2 6mm X 13mm OBROUND HOLE 5 PL HANGER BRACKET 7 178mm 7 178mm 16 5 16 414mm 1 1 4 32mm 1 1 4 32mm Single Rough In Fig 1 VRC8WS REDUCE HEIGHT BY 3 FOR INSTALLATION OF CHILDREN S ADA COOLER LEGEN...

Page 4: ...mm 7 178mm 1 1 4 32mm 1 1 4 32mm 16 5 16 414mm O 5 16 8mm HOLES 3 PL 5 3 4 146mm 5 3 4 146mm 1 3 8 35mm 1 3 8 35mm 18 1 2 470mm 3 1 2 89mm 4 1 2 114mm 6 1 4 159mm Two Level Rough In Fig 2 VRCTL8WS RED...

Page 5: ...5mm 5 3 4 146mm 5 3 4 146mm 1 3 8 35mm 1 3 8 35mm 18 1 16 459mm 7 178mm 7 178mm 16 5 16 414mm 1 1 4 32mm 1 1 4 32mm VRCTLR8WS REDUCE HEIGHT BY 3 FOR INSTALLATION OF CHILDREN S ADA COOLER LEGEND A RECO...

Page 6: ...s and water inlet Connect black reset button wires from non refrigerated unit to the black wires on the refrigerated unit see step 4 6a For Reversed Two Level Model Installations Secure refrigerated u...

Page 7: ...Water Cooler The water line and Remote Reset Button Wires will still be connected from the Water Cooler to the Bottle Filler 3 For Two Level Model Installations Loosen but DO NOT remove the Pinned To...

Page 8: ...back in run mode 2 When the display changes to SETTINGS depress the button again The display will change to show RNG SET Range set for IR sensor UNIT TYP Type of unit REFRIG or NON REFRIG RST BCNT Res...

Page 9: ...om below 2 When the display changes to SETTINGS depress the button again The display will change to show RNG SET Range set for IR sensor UNIT TYP Type of unit REFRIG or NON RFRG FLT SIZE Select filter...

Page 10: ...ts Kit Electrical Package 220V Kit Solenoid Valve Replacement 220V Kit Drain Pad Kit Button Assembly Kit Top Cover Replacement Kit Gasket VR BF Tower Basin Kit Reset Switch Kit Micro Switch PART NO EL...

Reviews: