Elkay LZSTL8WSL2K Installation, Care & Use Manual Download Page 2

Page 2

LZSTL8WS_2D

1000002481  (Rev. C - 11/15)

Installation

For correct and safe installation, please read these instructions completely.

     •     All Installation work must be performed by an authorized service personnel.

     •     Disconnect electrical supply serving the Installation area to reduce risk of electrocution.

     •     Unit not suitable for installations where water jets could be used. 

DANGER

WARNING

     •     Shut off water supply serving the Installation area to reduce risk of water damage.

     •     Ensure proper ventilation by maintaining clearance from cabinet louvers to wall on each side of Cooler as specified in Rough-In.

     •     Never wire compressor directly to electrical supply.

     •     Thoroughly flush all water lines and fittings of all foreign matter before connecting to Cooler.

     •     Warranty is void if Installation is not made in accordance with current Manufacturing instructions.

CAUTION

     •     Hose-sets are not to be used for connecting to water mains.

     •     If inlet pressure is above 100 psig (0.69 MPa), a pressure regulator must be installed in water supply line. Any damage caused by

           reason of connecting this product to water supply line pressure outside it’s rated pressure, is not covered by warranty.

     •     Tools/Items required but not provided.

                 o       Water Shut-off Valve with 3/8” (9.5mm) compression outlet.

                 o       Waste Trap (non-metallic)

                 o       Safety Glasses

                 o       Protective Gloves

                 o       5/16” (8mm) Hex Socket or Flathead Screwdriver

                 o       5/32” (4mm) Hex Key

                 o       Fasteners for wall type.

Installation: Cooler Mounting

  1. Remove Hanger Bracket (Item 1) fastened to back of cooler by removing one (1) screw.

  2. Mount Hanger Bracket as shown in Figure 5, 6, 7, or 8.  

   •     NOTE: Hanger Bracket MUST be supported securely. Add fixture support carrier if wall will not provide adequate support. Anchor

          hanger securely to wall using all six (6) 1/4” (6.4mm) diameter mounting holes.

  3. Hang Cooler on the Hanger Bracket. Be certain the Hanger Bracket is engaged properly in the slots on the cooler back as shown in

      Figure 5, 6, 7, or 8.  

  4. Remove the four (4) screws holding the lower front panel at the bottom of cooler. Remove the front panel by pulling straight down and set

      aside.

Installation: Water Line connection

  1. Ensure Mains Water Supply has Water Shut-off Valve with 3/8” (9.5mm) compression outlet.

  2. Connect loose end of supplied 3/8” (9.5mm) unplated copper tube to Water Shut-off Valve. 

   •     NOTE: If 3/8” (9.5mm) copper tube must be cut for proper fit, remove all burrs from the outside of tube and re-flush before use.

  3. Install waste trap. Remove the slip nut and gasket from the waste trap and install them on the cooler waste line making sure that the end of

      the waste line fits into the waste trap. Assemble the slip nut and gasket to the waste trap and tighten securely.

   •     IMPORTANT: If it is necessary to cut the drain, loosen the screw at the black rubber boot and remove tube, check for leaks after

          reassembly

  4. It is recommended that the waste trap be insulated to avoid excessive condensation due to chilled water running through the waste trap.

  5. Install filter cartridge.  Remove filter from carton, remove protective cap, and attach filter to filter head by firmly inserting into head and rotating

      filter clockwise.  

   •     IMPORTANT:  DO NOT TURN ON WATER BEFORE INSTALLING BOTTLE FILLER

Installation: Bottle Filler

1.  Remove two (2) mounting screws holding top cover to bottle filler with a 5/32” (4mm) Hex Key (See Figure 2).  Remove top cover.  Note:  Do not 

discard mounting screws; they will be needed to re-install top cover.  

2.  Remove wall mounting plate from bottle filler.  Place wall plate against wall on top of basin.  Center the wall plate side to side with the basin.  Mark 

the six (6) mounting holes with a pencil.  See Figure 5, 6, 7, or 8.    

3.  Remove the wall mounting plate from wall.  

Note:  

Mounting plate 

MUST 

be supported securely.  Add fixture support carrier if wall will not provide 

adequate support. 

4.  Install wall mounting plate to wall using six (6) 7/16” (11.1mm) obround mounting holes (mounting bolts not provided).  See Figure 1.  Use 

appropriate fasteners for your wall type.    

5.  Feed 3/8” (9.5mm) water line through hole in tower/basin gasket.  See Figure 3. 

6.  Install gasket on bottom of bottle filler tower with gasket support bracket, (2) washers, and (2) screws.  See Figure 4.

7.  Feed modular (C-13) end of International Power Cord Set up through basin hole and hole in gasket.  Connect to Power Inlet on Bottle Filler.  Do 

not plug into electrical outlet. 

8.  With the power cord and waterline through the hole on top of water cooler place bottle filler on three (3) angled tabs protruding from the wall 

mounting plate installed on wall.  Make sure round boss in gasket fits in hole of basin.  

9.  Once bottle filler is installed on wall plate tabs, waterline, wires, and power cord are installed properly, push top of bottle filler toward wall and 

line up two (2) holes on top cover.  

10. Re-install top cover on bottle filler (See Figure 2) with two (2) mounting screws from step 1 above.  

Caution

:  Do not over tighten screws.  

11. Install remaining tube insulation to the water line from bottle filler, connect bottle filler waterline inside of the water cooler by connecting the 3/8” 

(9.5mm) waterline to the tee.  

Summary of Contents for LZSTL8WSL2K

Page 1: ...in voltage cycle and phase to that specified on nameplate Electrical supply must have Ground Fault Circuit Interrupter GFCI protection A means for disconnecting electrical supply to the unit must be...

Page 2: ...rap Remove the slip nut and gasket from the waste trap and install them on the cooler waste line making sure that the end of the waste line fits into the waste trap Assemble the slip nut and gasket to...

Page 3: ...to ensure proper clearance and free fan action 3 Connect plug end of International Power Cord Set sold separately into electrical outlet WARNING Exposed electrically energized components Use extreme c...

Page 4: ...4 11mm X 19mm OBROUND HOLES 6 15 381mm 2 7 8 73mm 2 51mm 51 9 16 1310mm 28 13 16 732mm 19 483mm 17 7 16 443mm 13 15 16 354mm 24 1 2 622mm 34 5 16 872mm 2 51mm 22 15 16 583mm 19 7 16 494mm 7 178mm 7 1...

Page 5: ...4 11mm X 19mm OBROUND HOLES 6 15 381mm 2 7 8 73mm 2 51mm 51 9 16 1310mm 28 13 16 732mm 19 483mm 17 7 16 443mm 13 15 16 354mm 24 1 2 622mm 34 5 16 872mm 2 51mm 22 15 16 583mm 19 7 16 494mm 7 178mm 7 17...

Page 6: ...ventilation can cause no cold water and compressor cycling on the compressor overload protector 5 Water Flow Confirm proper water flow If water flow is slow inspect filter or inline strainer for restr...

Page 7: ...be back in run mode Continued from below 2 When the display changes to SETTINGS depress the button again The display will change to show RNG SET Range set for IR sensor UNIT TYP Type of unit REFRIG o...

Page 8: ...ED IN POSITION PUSH IN COLLET TO RELEASE TUBE PUSHING TUBE IN BEFORE PULLING IT OUT HELPS TO RELEASE TUBE A B C Fig 12 DESCRIPTION 1 2 3 ITEM NO PART NO 51300C 98926C 0000000746 Filter Assy 3000 Gal K...

Page 9: ...15 LZSTL8WS_2D 19 8A 1 2A 12 19 12 19 4 28 19 16 2B 12 3 6 19 18 19 8B 21 1 15 16 13 5 3 6 5 17 20 7 26 31 22 32 23 Stream Height Adjustment Stream Height Adjustment Unit is pictured without bottle f...

Page 10: ...Side Push Drier Kit Drain Replacement EZTL8 Brkt Tube Ftg Clamp Kit Drain Replacement EZTLD BF Brkt Tube Ftg Clamp Kit Replacement Cap Screen O Ring Kit Solenoid Valve Regulator Assy Kit Flexi Bubble...

Page 11: ...basin assembly off the cooler frame 2 Disconnect two 2 black wires coming from the shroud assembly Black wire that connects from shroud assembly to solenoid valve Black wire that connects to white wi...

Page 12: ...n front of the frame tipped up as shown in picture to the right 2 Connect water line to solenoid valve Reference Figure 10 for operation of quick connect fittings 3 Connect two 2 black wires coming fr...

Page 13: ...piece to wrapper with 2 screws provided 3 Re install wrapper with 4 screws 4 Dispose of unused cover plate Right Hand Wrapper Low Side 1 Remove existing wrapper by removing the 4 screws from bottom 2...

Page 14: ...ev C 11 15 PLUMBING DIAGRAMS VERSATILE BI LEVEL Barb capped when not used Barb capped when not used Barb capped when not used Barb capped when not used Bottle Filler Drain Bottle Filler Drain Bottle F...

Page 15: ...Refrig unit L H Non Refrig unit Bubbler Bubbler Evaporator 3 8 Water Inlet Tee 3 8 Water Line from Bottle Filling Unit H Filter Assembly 1 4 Union Solenoid Valve Solenoid Valve PLUMBING DIAGRAMS FOR E...

Reviews: